Wireless distributed environmental sensor networks for air pollution measurement-the promise and the current reality

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

  • David M. Broday
  • Alexander Arpaci
  • Alena Bartonova
  • Nuría Castell-Balaguer
  • Cole-Hunter, Tom
  • Franck R. Dauge
  • Barak Fishbain
  • Rod L. Jones
  • Karen Galea
  • Milena Jovasevic-Stojanovic
  • David Kocman
  • Tania Martinez-Iñiguez
  • Mark Nieuwenhuijsen
  • Johanna Robinson
  • Vlasta Svecova
  • Phong Thai
  • Citi-Sense Project Collaborators

The evaluation of the effects of air pollution on public health and human-wellbeing requires reliable data. Standard air quality monitoring stations provide accurate measurements of airborne pollutant levels, but, due to their sparse distribution, they cannot capture accurately the spatial variability of air pollutant concentrations within cities. Dedicated in-depth field campaigns have dense spatial coverage of the measurements but are held for relatively short time periods. Hence, their representativeness is limited. Moreover, the oftentimes integrated measurements represent time-averaged records. Recent advances in communication and sensor technologies enable the deployment of dense grids ofWireless Distributed Environmental Sensor Networks for air quality monitoring, yet their capability to capture urban-scale spatiotemporal pollutant patterns has not been thoroughly examined to date. Here, we summarize our studies on the practicalities of using data streams from sensor nodes for air quality measurement and the required methods to tune the results to different stakeholders and applications. We summarize the results from eight cities across Europe, five sensor technologies-three stationary (with one tested also while moving) and two personal sensor platforms, and eight ambient pollutants. Overall, few sensors showed an exceptional and consistent performance, which can shed light on the fine spatiotemporal urban variability of pollutant concentrations. Stationary sensor nodes were more reliable than personal nodes. In general, the sensor measurements tend to suffer from the interference of various environmental factors and require frequent calibrations. This calls for the development of suitable field calibration procedures, and several such in situ field calibrations are presented.

OriginalsprogEngelsk
Artikelnummer2263
TidsskriftSensors (Switzerland)
Vol/bind17
Udgave nummer10
ISSN1424-8220
DOI
StatusUdgivet - okt. 2017
Eksternt udgivetJa

Bibliografisk note

Publisher Copyright:
© 2017 by the authors. Licensee MDPI, Basel, Switzerland.

ID: 346135965