UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water. / Clauson-Kaas, Frederik; Hansen, Hans Chr. Bruun; Strobel, Bjarne W.

I: Analytical and Bioanalytical Chemistry, Bind 408, Nr. 28, 2016, s. 7981-7990.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Clauson-Kaas, F, Hansen, HCB & Strobel, BW 2016, 'UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water', Analytical and Bioanalytical Chemistry, bind 408, nr. 28, s. 7981-7990. https://doi.org/10.1007/s00216-016-9895-z

APA

Clauson-Kaas, F., Hansen, H. C. B., & Strobel, B. W. (2016). UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water. Analytical and Bioanalytical Chemistry, 408(28), 7981-7990. https://doi.org/10.1007/s00216-016-9895-z

Vancouver

Clauson-Kaas F, Hansen HCB, Strobel BW. UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water. Analytical and Bioanalytical Chemistry. 2016;408(28):7981-7990. https://doi.org/10.1007/s00216-016-9895-z

Author

Clauson-Kaas, Frederik ; Hansen, Hans Chr. Bruun ; Strobel, Bjarne W. / UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water. I: Analytical and Bioanalytical Chemistry. 2016 ; Bind 408, Nr. 28. s. 7981-7990.

Bibtex

@article{d6411d5ab452408dbe01cd7331b2d331,
title = "UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water",
abstract = "The naturally occurring carcinogen ptaquiloside and its degradation product pterosin B are found in water leaching from bracken stands. The objective of this work is to present a new sample preservation method and a fast UPLC-MS/MS method for quantification of ptaquiloside and pterosin B in environmental water samples, employing a novel internal standard. A faster, reliable, and efficient method was developed for isolation of high purity ptaquiloside and pterosin B from plant material for use as analytical standards, with purity verified by (1)H-NMR. The chemical analysis was performed by cleanup and preconcentration of samples with solid phase extraction, before analyte quantification with UPLC-MS/MS. By including gradient elution and optimizing the liquid chromatography mobile phase buffer system, a total run cycle of 5 min was achieved, with method detection limits, including preconcentration, of 8 and 4 ng/L for ptaquiloside and pterosin B, respectively. The use of loganin as internal standard improved repeatability of the determination of both analytes, though it could not be employed for sample preparation. Buffering raw water samples in situ with ammonium acetate to pH ∼5.5 decisively increased sample integrity at realistic transportation and storing conditions prior to extraction. Groundwater samples collected in November 2015 at the shallow water table below a Danish bracken stand were preserved and analyzed using the above methods, and PTA concentrations of 3.8 ± 0.24 μg/L (±sd, n = 3) were found, much higher than previously reported. Graphical abstract Workflow overview of ptaquiloside determination.",
author = "Frederik Clauson-Kaas and Hansen, {Hans Chr. Bruun} and Strobel, {Bjarne W.}",
year = "2016",
doi = "10.1007/s00216-016-9895-z",
language = "English",
volume = "408",
pages = "7981--7990",
journal = "Analytical and Bioanalytical Chemistry",
issn = "1618-2642",
publisher = "Springer",
number = "28",

}

RIS

TY - JOUR

T1 - UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water

AU - Clauson-Kaas, Frederik

AU - Hansen, Hans Chr. Bruun

AU - Strobel, Bjarne W.

PY - 2016

Y1 - 2016

N2 - The naturally occurring carcinogen ptaquiloside and its degradation product pterosin B are found in water leaching from bracken stands. The objective of this work is to present a new sample preservation method and a fast UPLC-MS/MS method for quantification of ptaquiloside and pterosin B in environmental water samples, employing a novel internal standard. A faster, reliable, and efficient method was developed for isolation of high purity ptaquiloside and pterosin B from plant material for use as analytical standards, with purity verified by (1)H-NMR. The chemical analysis was performed by cleanup and preconcentration of samples with solid phase extraction, before analyte quantification with UPLC-MS/MS. By including gradient elution and optimizing the liquid chromatography mobile phase buffer system, a total run cycle of 5 min was achieved, with method detection limits, including preconcentration, of 8 and 4 ng/L for ptaquiloside and pterosin B, respectively. The use of loganin as internal standard improved repeatability of the determination of both analytes, though it could not be employed for sample preparation. Buffering raw water samples in situ with ammonium acetate to pH ∼5.5 decisively increased sample integrity at realistic transportation and storing conditions prior to extraction. Groundwater samples collected in November 2015 at the shallow water table below a Danish bracken stand were preserved and analyzed using the above methods, and PTA concentrations of 3.8 ± 0.24 μg/L (±sd, n = 3) were found, much higher than previously reported. Graphical abstract Workflow overview of ptaquiloside determination.

AB - The naturally occurring carcinogen ptaquiloside and its degradation product pterosin B are found in water leaching from bracken stands. The objective of this work is to present a new sample preservation method and a fast UPLC-MS/MS method for quantification of ptaquiloside and pterosin B in environmental water samples, employing a novel internal standard. A faster, reliable, and efficient method was developed for isolation of high purity ptaquiloside and pterosin B from plant material for use as analytical standards, with purity verified by (1)H-NMR. The chemical analysis was performed by cleanup and preconcentration of samples with solid phase extraction, before analyte quantification with UPLC-MS/MS. By including gradient elution and optimizing the liquid chromatography mobile phase buffer system, a total run cycle of 5 min was achieved, with method detection limits, including preconcentration, of 8 and 4 ng/L for ptaquiloside and pterosin B, respectively. The use of loganin as internal standard improved repeatability of the determination of both analytes, though it could not be employed for sample preparation. Buffering raw water samples in situ with ammonium acetate to pH ∼5.5 decisively increased sample integrity at realistic transportation and storing conditions prior to extraction. Groundwater samples collected in November 2015 at the shallow water table below a Danish bracken stand were preserved and analyzed using the above methods, and PTA concentrations of 3.8 ± 0.24 μg/L (±sd, n = 3) were found, much higher than previously reported. Graphical abstract Workflow overview of ptaquiloside determination.

U2 - 10.1007/s00216-016-9895-z

DO - 10.1007/s00216-016-9895-z

M3 - Journal article

C2 - 27590319

VL - 408

SP - 7981

EP - 7990

JO - Analytical and Bioanalytical Chemistry

JF - Analytical and Bioanalytical Chemistry

SN - 1618-2642

IS - 28

ER -

ID: 166197290