Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch. / Stürup, Stefan.

I: Journal of Analytical Atomic Spectrometry, Bind 17, Nr. 1, 09.02.2002, s. 1-7.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Stürup, S 2002, 'Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch', Journal of Analytical Atomic Spectrometry, bind 17, nr. 1, s. 1-7. https://doi.org/10.1039/b107313n

APA

Stürup, S. (2002). Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch. Journal of Analytical Atomic Spectrometry, 17(1), 1-7. https://doi.org/10.1039/b107313n

Vancouver

Stürup S. Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch. Journal of Analytical Atomic Spectrometry. 2002 feb. 9;17(1):1-7. https://doi.org/10.1039/b107313n

Author

Stürup, Stefan. / Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch. I: Journal of Analytical Atomic Spectrometry. 2002 ; Bind 17, Nr. 1. s. 1-7.

Bibtex

@article{91746374460d4f96bc4651b7ab20de8d,
title = "Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch",
abstract = "A new method for the measurement of calcium isotope ratios and total calcium, using a double focusing sector field inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with a shielded torch, is presented. The method was applied for the measurement of the 44Ca/43Ca, 42Ca/43Ca and 44Ca/42Ca ratios and total calcium by isotope dilution in urine samples from two different nutritional experiments set up to determine the calcium absorption from various foods. The isotope ratios were measured with a precision of 0.25%, 0.23% and 0.05% RSD for 44Ca/43Ca, 42Ca/43Ca and 44Ca/42Ca, respectively. The precision of the 44Ca/42Ca ratio is only limited by counting statistics, whereas the precision is limited by uncertainty from the needed background and interference corrections when the minor 43Ca isotope is used for analysis. Uncertainty calculations on the determination of calcium absorption in the nutritional experiments are presented. These calculations show that, for a double stable isotope procedure (administration of enriched stable 44Ca and 42Ca), the overall uncertainty is controlled by the precision of the ICP-MS measurement of the isotope ratios (44Ca/43Ca, 42Ca/43Ca), whereas, for a mixed radioisotope-stable isotope procedure (administration of enriched stable 44Ca and the 47Ca radioisotope), the overall uncertainty is mainly controlled by the uncertainty in the measurement of total calcium by isotope dilution ICP-MS. From these results, it was concluded that, when optimizing the performance of nutritional experiments, the emphasis should be placed on different parameters depending on the exact analysis involved. The results also show that uncertainty calculations are very useful in pinpointing the critical parameters of an experiment.",
author = "Stefan St{\"u}rup",
year = "2002",
month = feb,
day = "9",
doi = "10.1039/b107313n",
language = "English",
volume = "17",
pages = "1--7",
journal = "Journal of Analytical Atomic Spectrometry",
issn = "0267-9477",
publisher = "Royal Society of Chemistry",
number = "1",

}

RIS

TY - JOUR

T1 - Uncertainty calculation on the determination of calcium absorption in nutritional experiments with enriched stable isotopes and detection by double focusing sector field ICP-MS with a shielded torch

AU - Stürup, Stefan

PY - 2002/2/9

Y1 - 2002/2/9

N2 - A new method for the measurement of calcium isotope ratios and total calcium, using a double focusing sector field inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with a shielded torch, is presented. The method was applied for the measurement of the 44Ca/43Ca, 42Ca/43Ca and 44Ca/42Ca ratios and total calcium by isotope dilution in urine samples from two different nutritional experiments set up to determine the calcium absorption from various foods. The isotope ratios were measured with a precision of 0.25%, 0.23% and 0.05% RSD for 44Ca/43Ca, 42Ca/43Ca and 44Ca/42Ca, respectively. The precision of the 44Ca/42Ca ratio is only limited by counting statistics, whereas the precision is limited by uncertainty from the needed background and interference corrections when the minor 43Ca isotope is used for analysis. Uncertainty calculations on the determination of calcium absorption in the nutritional experiments are presented. These calculations show that, for a double stable isotope procedure (administration of enriched stable 44Ca and 42Ca), the overall uncertainty is controlled by the precision of the ICP-MS measurement of the isotope ratios (44Ca/43Ca, 42Ca/43Ca), whereas, for a mixed radioisotope-stable isotope procedure (administration of enriched stable 44Ca and the 47Ca radioisotope), the overall uncertainty is mainly controlled by the uncertainty in the measurement of total calcium by isotope dilution ICP-MS. From these results, it was concluded that, when optimizing the performance of nutritional experiments, the emphasis should be placed on different parameters depending on the exact analysis involved. The results also show that uncertainty calculations are very useful in pinpointing the critical parameters of an experiment.

AB - A new method for the measurement of calcium isotope ratios and total calcium, using a double focusing sector field inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with a shielded torch, is presented. The method was applied for the measurement of the 44Ca/43Ca, 42Ca/43Ca and 44Ca/42Ca ratios and total calcium by isotope dilution in urine samples from two different nutritional experiments set up to determine the calcium absorption from various foods. The isotope ratios were measured with a precision of 0.25%, 0.23% and 0.05% RSD for 44Ca/43Ca, 42Ca/43Ca and 44Ca/42Ca, respectively. The precision of the 44Ca/42Ca ratio is only limited by counting statistics, whereas the precision is limited by uncertainty from the needed background and interference corrections when the minor 43Ca isotope is used for analysis. Uncertainty calculations on the determination of calcium absorption in the nutritional experiments are presented. These calculations show that, for a double stable isotope procedure (administration of enriched stable 44Ca and 42Ca), the overall uncertainty is controlled by the precision of the ICP-MS measurement of the isotope ratios (44Ca/43Ca, 42Ca/43Ca), whereas, for a mixed radioisotope-stable isotope procedure (administration of enriched stable 44Ca and the 47Ca radioisotope), the overall uncertainty is mainly controlled by the uncertainty in the measurement of total calcium by isotope dilution ICP-MS. From these results, it was concluded that, when optimizing the performance of nutritional experiments, the emphasis should be placed on different parameters depending on the exact analysis involved. The results also show that uncertainty calculations are very useful in pinpointing the critical parameters of an experiment.

UR - http://www.scopus.com/inward/record.url?scp=0036007426&partnerID=8YFLogxK

U2 - 10.1039/b107313n

DO - 10.1039/b107313n

M3 - Journal article

AN - SCOPUS:0036007426

VL - 17

SP - 1

EP - 7

JO - Journal of Analytical Atomic Spectrometry

JF - Journal of Analytical Atomic Spectrometry

SN - 0267-9477

IS - 1

ER -

ID: 199497901