Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation. / Perner, A; Faber, T.

I: Acta Anaesthesiologica Scandinavica, Bind 50, Nr. 9, 10.2006, s. 1068-73.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Perner, A & Faber, T 2006, 'Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation', Acta Anaesthesiologica Scandinavica, bind 50, nr. 9, s. 1068-73. https://doi.org/10.1111/j.1399-6576.2006.01120.x

APA

Perner, A., & Faber, T. (2006). Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation. Acta Anaesthesiologica Scandinavica, 50(9), 1068-73. https://doi.org/10.1111/j.1399-6576.2006.01120.x

Vancouver

Perner A, Faber T. Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation. Acta Anaesthesiologica Scandinavica. 2006 okt.;50(9):1068-73. https://doi.org/10.1111/j.1399-6576.2006.01120.x

Author

Perner, A ; Faber, T. / Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation. I: Acta Anaesthesiologica Scandinavica. 2006 ; Bind 50, Nr. 9. s. 1068-73.

Bibtex

@article{51e344d292004ea6903594e176dc6452,
title = "Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation",
abstract = "Stroke volume variation (SVV)--as measured by the pulse contour cardiac output (PiCCO) system--predicts the cardiac output response to a fluid challenge in patients on controlled ventilation. Whether this applies to patients on pressure support ventilation is unknown.",
author = "A Perner and T Faber",
year = "2006",
month = oct,
doi = "http://dx.doi.org/10.1111/j.1399-6576.2006.01120.x",
language = "English",
volume = "50",
pages = "1068--73",
journal = "Acta Anaesthesiologica Scandinavica",
issn = "0001-5172",
publisher = "Wiley-Blackwell",
number = "9",

}

RIS

TY - JOUR

T1 - Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation

AU - Perner, A

AU - Faber, T

PY - 2006/10

Y1 - 2006/10

N2 - Stroke volume variation (SVV)--as measured by the pulse contour cardiac output (PiCCO) system--predicts the cardiac output response to a fluid challenge in patients on controlled ventilation. Whether this applies to patients on pressure support ventilation is unknown.

AB - Stroke volume variation (SVV)--as measured by the pulse contour cardiac output (PiCCO) system--predicts the cardiac output response to a fluid challenge in patients on controlled ventilation. Whether this applies to patients on pressure support ventilation is unknown.