Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry. / Gjorup, Caroline A; Zerahn, Bo; Juul, Sarah; Hendel, Helle W.; Christensen, Karl Bang; Hölmich, Lisbet R.

I: Journal of Clinical Densitometry, Bind 20, Nr. 1, 2017, s. 82–96.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Gjorup, CA, Zerahn, B, Juul, S, Hendel, HW, Christensen, KB & Hölmich, LR 2017, 'Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry', Journal of Clinical Densitometry, bind 20, nr. 1, s. 82–96. https://doi.org/10.1016/j.jocd.2016.08.009

APA

Gjorup, C. A., Zerahn, B., Juul, S., Hendel, H. W., Christensen, K. B., & Hölmich, L. R. (2017). Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry. Journal of Clinical Densitometry, 20(1), 82–96. https://doi.org/10.1016/j.jocd.2016.08.009

Vancouver

Gjorup CA, Zerahn B, Juul S, Hendel HW, Christensen KB, Hölmich LR. Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry. Journal of Clinical Densitometry. 2017;20(1): 82–96. https://doi.org/10.1016/j.jocd.2016.08.009

Author

Gjorup, Caroline A ; Zerahn, Bo ; Juul, Sarah ; Hendel, Helle W. ; Christensen, Karl Bang ; Hölmich, Lisbet R. / Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry. I: Journal of Clinical Densitometry. 2017 ; Bind 20, Nr. 1. s. 82–96.

Bibtex

@article{bea3c0073d8c41c292558a0a93d5d691,
title = "Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry",
abstract = "Lower limb lymphedema is a dynamic condition in which tissue composition and volume measurements are affected. Various definitions of lower limb lymphedema exist but volume differences between the limbs are widely used. It is therefore necessary to have a readily available noninvasive measurement technique allowing multiple measurements of the lower limbs. This study investigated the repeatability of duplicate volume and regional body composition measurements of the lower limb using the GE Lunar Prodigy dual-energy X-ray absorptiometry (DXA) scanner Prodigy (GE Medical Systems, Madison, WI). Twenty-seven participants (54 limbs), 14 women and 13 men aged 33-71 years with body mass index ranging from 14 to 32 kg/m(2) were recruited. Duplicate whole-body DXA scans were performed with repositioning between examinations. Regions of interest were manually drawn for the thigh, lower leg, and foot, and total volume was calculated using the density of bone mineral content, fat, and lean mass. The repeatability of the volume of the lower limb and regional thigh and lower leg tissue composition (bone mineral content, fat, and lean mass) was good with intraclass correlation coefficient values of 0.97 to 0.99, and narrow limits of agreement on the Bland-Altman plots. These results confirm DXA to be a highly repeatable method for volume and tissue composition measurements of the lower limb. In a population at risk of lymphedema, DXA offers a clinically readily available noninvasive method allowing multiple measurements of volume and tissue composition on a routine basis, important for diagnosing, monitoring, managing, and researching lymphedema.",
author = "Gjorup, {Caroline A} and Bo Zerahn and Sarah Juul and Hendel, {Helle W.} and Christensen, {Karl Bang} and H{\"o}lmich, {Lisbet R.}",
note = "Copyright {\textcopyright} 2016 International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.",
year = "2017",
doi = "10.1016/j.jocd.2016.08.009",
language = "English",
volume = "20",
pages = " 82–96",
journal = "Journal of Clinical Densitometry",
issn = "1094-6950",
publisher = "Elsevier",
number = "1",

}

RIS

TY - JOUR

T1 - Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry

AU - Gjorup, Caroline A

AU - Zerahn, Bo

AU - Juul, Sarah

AU - Hendel, Helle W.

AU - Christensen, Karl Bang

AU - Hölmich, Lisbet R.

N1 - Copyright © 2016 International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

PY - 2017

Y1 - 2017

N2 - Lower limb lymphedema is a dynamic condition in which tissue composition and volume measurements are affected. Various definitions of lower limb lymphedema exist but volume differences between the limbs are widely used. It is therefore necessary to have a readily available noninvasive measurement technique allowing multiple measurements of the lower limbs. This study investigated the repeatability of duplicate volume and regional body composition measurements of the lower limb using the GE Lunar Prodigy dual-energy X-ray absorptiometry (DXA) scanner Prodigy (GE Medical Systems, Madison, WI). Twenty-seven participants (54 limbs), 14 women and 13 men aged 33-71 years with body mass index ranging from 14 to 32 kg/m(2) were recruited. Duplicate whole-body DXA scans were performed with repositioning between examinations. Regions of interest were manually drawn for the thigh, lower leg, and foot, and total volume was calculated using the density of bone mineral content, fat, and lean mass. The repeatability of the volume of the lower limb and regional thigh and lower leg tissue composition (bone mineral content, fat, and lean mass) was good with intraclass correlation coefficient values of 0.97 to 0.99, and narrow limits of agreement on the Bland-Altman plots. These results confirm DXA to be a highly repeatable method for volume and tissue composition measurements of the lower limb. In a population at risk of lymphedema, DXA offers a clinically readily available noninvasive method allowing multiple measurements of volume and tissue composition on a routine basis, important for diagnosing, monitoring, managing, and researching lymphedema.

AB - Lower limb lymphedema is a dynamic condition in which tissue composition and volume measurements are affected. Various definitions of lower limb lymphedema exist but volume differences between the limbs are widely used. It is therefore necessary to have a readily available noninvasive measurement technique allowing multiple measurements of the lower limbs. This study investigated the repeatability of duplicate volume and regional body composition measurements of the lower limb using the GE Lunar Prodigy dual-energy X-ray absorptiometry (DXA) scanner Prodigy (GE Medical Systems, Madison, WI). Twenty-seven participants (54 limbs), 14 women and 13 men aged 33-71 years with body mass index ranging from 14 to 32 kg/m(2) were recruited. Duplicate whole-body DXA scans were performed with repositioning between examinations. Regions of interest were manually drawn for the thigh, lower leg, and foot, and total volume was calculated using the density of bone mineral content, fat, and lean mass. The repeatability of the volume of the lower limb and regional thigh and lower leg tissue composition (bone mineral content, fat, and lean mass) was good with intraclass correlation coefficient values of 0.97 to 0.99, and narrow limits of agreement on the Bland-Altman plots. These results confirm DXA to be a highly repeatable method for volume and tissue composition measurements of the lower limb. In a population at risk of lymphedema, DXA offers a clinically readily available noninvasive method allowing multiple measurements of volume and tissue composition on a routine basis, important for diagnosing, monitoring, managing, and researching lymphedema.

U2 - 10.1016/j.jocd.2016.08.009

DO - 10.1016/j.jocd.2016.08.009

M3 - Journal article

C2 - 27634336

VL - 20

SP - 82

EP - 96

JO - Journal of Clinical Densitometry

JF - Journal of Clinical Densitometry

SN - 1094-6950

IS - 1

ER -

ID: 166376533