Ictal and interictal SPECT with 99m Tc-HMPAO in presurgical epilepsy. II: Methodological considerations on hyper- and hypoperfusion

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Dokumenter

  • Fulltext

    Forlagets udgivne version, 545 KB, PDF-dokument

Objective
Single-photon emission computed tomography (SPECT) with the tracer 99mTc-HMPAO is a method to visualize the cerebral hyperperfusion during an epileptic seizure and thus localize the epileptogenic zone and seizure propagation. Subtraction of interictal from Ictal SPECT Co-registered to MRI (SISCOM) visualizes areas with relative increases in cerebral blood flow. The purpose of this retrospective study is to explore the added value of visualizing areas of hypoperfusion as well as hyperperfusion, so-called reversed SISCOM.

Methods
Fifty-six patients operated for epilepsy who had been investigated with SISCOM were included in the analysis. The patients were divided into two groups based on seizure duration after tracer injection, above or below 30 s. The preoperative SISCOM description was compared to the area of resection and given a concordance score. The 56 SISCOM were recalculated visualizing also areas of hypoperfusion and again compared to the site of resection using the same scale of concordance. The reversed SISCOM were categorized into three subgroups: “Altered Conclusion,” “Confirmed Conclusion,” and “Adds Nothing.” If an area of hyperperfusion had an area of hypoperfusion in close proximity, it was re-interpreted as noise, thus possibly altering the conclusion. If the areas of hypoperfusion were in the opposite hemisphere it was interpreted as confirming factor. Further the concordance scores from conventional SISCOM and reversed SISCOM was compared to surgical outcome to explore the difference in sensitivity, positive predictive value (PPV), and odds ratio.

Results
In approximately half of the cases reversed SISCOM added additional value, meaning either altered the conclusion or confirmed the conclusion. The sensitivity, PPV, and odds ratio was also better in the subgroup of long, >30 s seizure duration after injection, and got worse in the group with short, <30 s seizure duration after injection.

Significance
Adding reversed SISCOM performed better than conventional SISCOM at predicting good surgical outcome.
OriginalsprogEngelsk
TidsskriftEpilepsia open
Vol/bind8
Udgave nummer4
Sider (fra-til)1503-1511
Antal sider9
ISSN2470-9239
DOI
StatusUdgivet - 2023

Bibliografisk note

© 2023 The Authors. Epilepsia Open published by Wiley Periodicals LLC on behalf of International League Against Epilepsy.

ID: 371912433