Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T. / Larsson, H.B.W.; Hansen, A.E.; Berg, H.K.; Rostrup, E.; Haraldseth, O.

I: Journal of Magnetic Resonance Imaging, Bind 27, Nr. 4, 2008, s. 754-762.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Larsson, HBW, Hansen, AE, Berg, HK, Rostrup, E & Haraldseth, O 2008, 'Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T', Journal of Magnetic Resonance Imaging, bind 27, nr. 4, s. 754-762.

APA

Larsson, H. B. W., Hansen, A. E., Berg, H. K., Rostrup, E., & Haraldseth, O. (2008). Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T. Journal of Magnetic Resonance Imaging, 27(4), 754-762.

Vancouver

Larsson HBW, Hansen AE, Berg HK, Rostrup E, Haraldseth O. Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T. Journal of Magnetic Resonance Imaging. 2008;27(4):754-762.

Author

Larsson, H.B.W. ; Hansen, A.E. ; Berg, H.K. ; Rostrup, E. ; Haraldseth, O. / Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T. I: Journal of Magnetic Resonance Imaging. 2008 ; Bind 27, Nr. 4. s. 754-762.

Bibtex

@article{962c1ef0063911deb05e000ea68e967b,
title = "Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T",
abstract = "Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast-enhanced T-1-weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole-body magnet and a T-1-weighted fast field echo sequence. The input function was obtained from the internal carotid artery. An initial T-1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)based calculation of cerebral perfusion (CBF) was performed using Tikhonov's procedure of deconvolution. Seven patients with acute optic neuritis and two patients with acute stroke were investigated. Results: The mean perfusion value for ROIs in gray matter was 62 mL/100g/min and 21 mL/100g/min in white matter in patients with acute optic neuritis. The perfusion inside the infarct core was, 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast-enhanced MRI. These values correspond,to expected values from established PET methods. Furthermore, at 3T pixelwise calculation can be performed, allowing construction of CBF maps Udgivelsesdato: 2008/4",
author = "H.B.W. Larsson and A.E. Hansen and H.K. Berg and E. Rostrup and O. Haraldseth",
note = "Times Cited: 0ArticleEnglishLarsson, H. B. WUniv Copenhagen, Glostrup Hosp, Funct Imaging Unit, Ndr Ringvej 57, DK-2600 Glostrup, DenmarkCited References Count: 35284MCJOHN WILEY & SONS INC111 RIVER ST, HOBOKEN, NJ 07030 USAHOBOKEN",
year = "2008",
language = "English",
volume = "27",
pages = "754--762",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "JohnWiley & Sons, Inc.",
number = "4",

}

RIS

TY - JOUR

T1 - Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T

AU - Larsson, H.B.W.

AU - Hansen, A.E.

AU - Berg, H.K.

AU - Rostrup, E.

AU - Haraldseth, O.

N1 - Times Cited: 0ArticleEnglishLarsson, H. B. WUniv Copenhagen, Glostrup Hosp, Funct Imaging Unit, Ndr Ringvej 57, DK-2600 Glostrup, DenmarkCited References Count: 35284MCJOHN WILEY & SONS INC111 RIVER ST, HOBOKEN, NJ 07030 USAHOBOKEN

PY - 2008

Y1 - 2008

N2 - Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast-enhanced T-1-weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole-body magnet and a T-1-weighted fast field echo sequence. The input function was obtained from the internal carotid artery. An initial T-1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)based calculation of cerebral perfusion (CBF) was performed using Tikhonov's procedure of deconvolution. Seven patients with acute optic neuritis and two patients with acute stroke were investigated. Results: The mean perfusion value for ROIs in gray matter was 62 mL/100g/min and 21 mL/100g/min in white matter in patients with acute optic neuritis. The perfusion inside the infarct core was, 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast-enhanced MRI. These values correspond,to expected values from established PET methods. Furthermore, at 3T pixelwise calculation can be performed, allowing construction of CBF maps Udgivelsesdato: 2008/4

AB - Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast-enhanced T-1-weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole-body magnet and a T-1-weighted fast field echo sequence. The input function was obtained from the internal carotid artery. An initial T-1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)based calculation of cerebral perfusion (CBF) was performed using Tikhonov's procedure of deconvolution. Seven patients with acute optic neuritis and two patients with acute stroke were investigated. Results: The mean perfusion value for ROIs in gray matter was 62 mL/100g/min and 21 mL/100g/min in white matter in patients with acute optic neuritis. The perfusion inside the infarct core was, 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast-enhanced MRI. These values correspond,to expected values from established PET methods. Furthermore, at 3T pixelwise calculation can be performed, allowing construction of CBF maps Udgivelsesdato: 2008/4

M3 - Journal article

VL - 27

SP - 754

EP - 762

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 4

ER -

ID: 10948269