Continuous monitoring is superior to manual measurements in detecting vital sign deviations in patients with COVID-19

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Dokumenter

  • Fulltext

    Forlagets udgivne version, 540 KB, PDF-dokument

  • Katja Kjær Grønbæk
  • Søren Møller Rasmussen
  • Natasha Hemicke Langer
  • Mette Vincentz
  • Anne Britt Oxbøll
  • Marlene Søgaard
  • Hussein Nasser Awada
  • Tomas O. Jensen
  • Magnus Thorsten Jensen
  • Helge B.D. Sørensen
  • Aasvang, Eske Kvanner
  • Meyhoff, Christian Sylvest

Background: Patients admitted to the emergency care setting with COVID-19-infection can suffer from sudden clinical deterioration, but the extent of deviating vital signs in this group is still unclear. Wireless technology monitors patient vital signs continuously and might detect deviations earlier than intermittent measurements. The aim of this study was to determine frequency and duration of vital sign deviations using continuous monitoring compared to manual measurements. A secondary analysis was to compare deviations in patients admitted to ICU or having fatal outcome vs. those that were not. Methods: Two wireless sensors continuously monitored (CM) respiratory rate (RR), heart rate (HR), and peripheral arterial oxygen saturation (SpO2). Frequency and duration of vital sign deviations were compared with point measurements performed by clinical staff according to regional guidelines, the National Early Warning Score (NEWS). Results: SpO2 < 92% for more than 60 min was detected in 92% of the patients with CM vs. 40% with NEWS (p <.00001). RR > 24 breaths per minute for more than 5 min were detected in 70% with CM vs. 33% using NEWS (p =.0001). HR ≥ 111 for more than 60 min was seen in 51% with CM and 22% with NEWS (p =.0002). Patients admitted to ICU or having fatal outcome had longer durations of RR > 24 brpm (p =.01), RR > 21 brpm (p =.01), SpO2 < 80% (p =.01), and SpO2 < 85% (p =.02) compared to patients that were not. Conclusion: Episodes of desaturation and tachypnea in hospitalized patients with COVID-19 infection are common and often not detected by routine measurements.

OriginalsprogEngelsk
TidsskriftActa Anaesthesiologica Scandinavica
Vol/bind67
Udgave nummer5
Sider (fra-til)640-648
Antal sider9
ISSN0001-5172
DOI
StatusUdgivet - 2023

Bibliografisk note

Publisher Copyright:
© 2023 The Authors. Acta Anaesthesiologica Scandinavica published by John Wiley & Sons Ltd on behalf of Acta Anaesthesiologica Scandinavica Foundation.

ID: 362902530