Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler

Publikation: Bidrag til bog/antologi/rapportKonferencebidrag i proceedingsForskningfagfællebedømt

Standard

Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler. / Stangegaard, Michael; Olsen, Addie Nina; Frøslev, Tobias G.; Hansen, Anders Johannes; Morling, Niels.

Progress in Forensic Genetics 13: Proceedings of the 23rd International ISFG Conference. red. / Niels Morling. Bind 2 Elsevier, 2009. s. 71-73 (Forensic Science International: Genetics Supplement Series; Nr. 1, Bind 2).

Publikation: Bidrag til bog/antologi/rapportKonferencebidrag i proceedingsForskningfagfællebedømt

Harvard

Stangegaard, M, Olsen, AN, Frøslev, TG, Hansen, AJ & Morling, N 2009, Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler. i N Morling (red.), Progress in Forensic Genetics 13: Proceedings of the 23rd International ISFG Conference. bind 2, Elsevier, Forensic Science International: Genetics Supplement Series, nr. 1, bind 2, s. 71-73, 23rd International ISFG Congress, Buenos Aires, Argentina, 14/09/2009.

APA

Stangegaard, M., Olsen, A. N., Frøslev, T. G., Hansen, A. J., & Morling, N. (2009). Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler. I N. Morling (red.), Progress in Forensic Genetics 13: Proceedings of the 23rd International ISFG Conference (Bind 2, s. 71-73). Elsevier. Forensic Science International: Genetics Supplement Series Bind 2 Nr. 1

Vancouver

Stangegaard M, Olsen AN, Frøslev TG, Hansen AJ, Morling N. Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler. I Morling N, red., Progress in Forensic Genetics 13: Proceedings of the 23rd International ISFG Conference. Bind 2. Elsevier. 2009. s. 71-73. (Forensic Science International: Genetics Supplement Series; Nr. 1, Bind 2).

Author

Stangegaard, Michael ; Olsen, Addie Nina ; Frøslev, Tobias G. ; Hansen, Anders Johannes ; Morling, Niels. / Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler. Progress in Forensic Genetics 13: Proceedings of the 23rd International ISFG Conference. red. / Niels Morling. Bind 2 Elsevier, 2009. s. 71-73 (Forensic Science International: Genetics Supplement Series; Nr. 1, Bind 2).

Bibtex

@inproceedings{6a03e100a2ab11debc73000ea68e967b,
title = "Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler",
abstract = "We have implemented and validated automated methods for washing FTA Card punches containing buccal samples and subsequent PCR setup using a Sias Xantus automated liquid handler. The automated methods were controlled by worklists generated by our LabWare Laboratory Information Management System (LIMS). The protocols were validated according to EN/ISO 17025 for use with STR amplifications kits AmpFlSTR« Identifiler« and Y-filer« (Applied Biosystems)",
author = "Michael Stangegaard and Olsen, {Addie Nina} and Fr{\o}slev, {Tobias G.} and Hansen, {Anders Johannes} and Niels Morling",
year = "2009",
language = "English",
volume = "2",
series = "Forensic Science International: Genetics Supplement Series",
publisher = "Elsevier",
number = "1",
pages = "71--73",
editor = "Niels Morling",
booktitle = "Progress in Forensic Genetics 13",
address = "Netherlands",
note = "null ; Conference date: 14-09-2009 Through 18-09-2009",

}

RIS

TY - GEN

T1 - Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler

AU - Stangegaard, Michael

AU - Olsen, Addie Nina

AU - Frøslev, Tobias G.

AU - Hansen, Anders Johannes

AU - Morling, Niels

PY - 2009

Y1 - 2009

N2 - We have implemented and validated automated methods for washing FTA Card punches containing buccal samples and subsequent PCR setup using a Sias Xantus automated liquid handler. The automated methods were controlled by worklists generated by our LabWare Laboratory Information Management System (LIMS). The protocols were validated according to EN/ISO 17025 for use with STR amplifications kits AmpFlSTR« Identifiler« and Y-filer« (Applied Biosystems)

AB - We have implemented and validated automated methods for washing FTA Card punches containing buccal samples and subsequent PCR setup using a Sias Xantus automated liquid handler. The automated methods were controlled by worklists generated by our LabWare Laboratory Information Management System (LIMS). The protocols were validated according to EN/ISO 17025 for use with STR amplifications kits AmpFlSTR« Identifiler« and Y-filer« (Applied Biosystems)

M3 - Article in proceedings

VL - 2

T3 - Forensic Science International: Genetics Supplement Series

SP - 71

EP - 73

BT - Progress in Forensic Genetics 13

A2 - Morling, Niels

PB - Elsevier

Y2 - 14 September 2009 through 18 September 2009

ER -

ID: 14464760