Adaptive process triage system cannot identify patients with gastrointestinal perforation

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Dokumenter

  • a5374

    Forlagets udgivne version, 468 KB, PDF-dokument

INTRODUCTION: Adaptive process triage (ADAPT) is a triage tool developed to assess the severity and address the priority of emergency patients. In 2009-2011, ADAPT was the most frequently used triage system in Denmark. Until now, no Danish triage system has been evaluated based on a selective group of patients in need of acute abdominal surgery. Gastrointestinal perforation (GIP) is acknowledged as one of the surgical conditions with the highest mortality rates. The aim of this study was to evaluate whether ADAPT can identify patients with GIP.

METHODS: All abdominal emergency laparoscopies and laparotomies performed over a one-year period at Herlev Hospital, Denmark, were included. Patient data and triage levels were collected from medical records. We defined patients suspected of less severe surgical illness as green-yellow and patients suspected of severe/life-threatening illness as orange-red.

RESULTS: A total of 803 patients with a known triage level were identified: 47% green, 38% yellow, 13% orange and 2% red. Of these patients, 136 were identified with a GIP. The negative predictive value was 83.2% (95% confidence interval: 80.1-85.7), meaning that one out of six abdominal surgery patients triaged as green or yellow had a GIP that was not identified by the triage system.

CONCLUSION: ADAPT is incapable of identifying one of the most critically ill patient groups in need of emergency abdominal surgery.

FUNDING: none.

TRIAL REGISTRATION: HEH-2013-034 I-Suite: 02336.

OriginalsprogEngelsk
ArtikelnummerA5374
TidsskriftDanish Medical Journal
Vol/bind64
Udgave nummer7
ISSN1603-9629
StatusUdgivet - 2017

Antal downloads er baseret på statistik fra Google Scholar og www.ku.dk


Ingen data tilgængelig

ID: 195512146