A case of safe and durable focal pulsed-field electroporation treatment of outflow tract premature ventricular contractions

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

A case of safe and durable focal pulsed-field electroporation treatment of outflow tract premature ventricular contractions. / Worck, René; Haugdal, Martin A.; Johannessen, Arne; Hansen, Morten Lock; Ruwald, Martin H.; Hansen, Jim.

I: Heart Rhythm O2, Bind 4, Nr. 7, 2023, s. 463-465.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Worck, R, Haugdal, MA, Johannessen, A, Hansen, ML, Ruwald, MH & Hansen, J 2023, 'A case of safe and durable focal pulsed-field electroporation treatment of outflow tract premature ventricular contractions', Heart Rhythm O2, bind 4, nr. 7, s. 463-465. https://doi.org/10.1016/j.hroo.2023.06.006

APA

Worck, R., Haugdal, M. A., Johannessen, A., Hansen, M. L., Ruwald, M. H., & Hansen, J. (2023). A case of safe and durable focal pulsed-field electroporation treatment of outflow tract premature ventricular contractions. Heart Rhythm O2, 4(7), 463-465. https://doi.org/10.1016/j.hroo.2023.06.006

Vancouver

Worck R, Haugdal MA, Johannessen A, Hansen ML, Ruwald MH, Hansen J. A case of safe and durable focal pulsed-field electroporation treatment of outflow tract premature ventricular contractions. Heart Rhythm O2. 2023;4(7):463-465. https://doi.org/10.1016/j.hroo.2023.06.006

Author

Worck, René ; Haugdal, Martin A. ; Johannessen, Arne ; Hansen, Morten Lock ; Ruwald, Martin H. ; Hansen, Jim. / A case of safe and durable focal pulsed-field electroporation treatment of outflow tract premature ventricular contractions. I: Heart Rhythm O2. 2023 ; Bind 4, Nr. 7. s. 463-465.

Bibtex

@article{0432986f40c54982948250597cab0375,
title = "A case of safe and durable focal pulsed-field electroporation treatment of outflow tract premature ventricular contractions",
keywords = "Durability, Outflow tract, Premature ventricular contractions, Pulsed-field electroporation, Safety",
author = "Ren{\'e} Worck and Haugdal, {Martin A.} and Arne Johannessen and Hansen, {Morten Lock} and Ruwald, {Martin H.} and Jim Hansen",
note = "Funding Information: This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors. Ren{\'e} Worck has received research grants and speaker honoraria from Biosense Webster. Jim Hansen has received research grants and speaker honoraria from Medtronic, Biosense Webster, and Boston Scientific. All other authors have no disclosures or conflicts of interest. All authors attest they meet the current ICMJE criteria for authorship. The patient provided informed consent. The research reported in this paper adhered to the CARE case report guidelines (www.care-statement.org)",
year = "2023",
doi = "10.1016/j.hroo.2023.06.006",
language = "English",
volume = "4",
pages = "463--465",
journal = "Heart Rhythm O2",
issn = "2666-5018",
publisher = "Elsevier",
number = "7",

}

RIS

TY - JOUR

T1 - A case of safe and durable focal pulsed-field electroporation treatment of outflow tract premature ventricular contractions

AU - Worck, René

AU - Haugdal, Martin A.

AU - Johannessen, Arne

AU - Hansen, Morten Lock

AU - Ruwald, Martin H.

AU - Hansen, Jim

N1 - Funding Information: This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors. René Worck has received research grants and speaker honoraria from Biosense Webster. Jim Hansen has received research grants and speaker honoraria from Medtronic, Biosense Webster, and Boston Scientific. All other authors have no disclosures or conflicts of interest. All authors attest they meet the current ICMJE criteria for authorship. The patient provided informed consent. The research reported in this paper adhered to the CARE case report guidelines (www.care-statement.org)

PY - 2023

Y1 - 2023

KW - Durability

KW - Outflow tract

KW - Premature ventricular contractions

KW - Pulsed-field electroporation

KW - Safety

UR - http://www.scopus.com/inward/record.url?scp=85163821560&partnerID=8YFLogxK

U2 - 10.1016/j.hroo.2023.06.006

DO - 10.1016/j.hroo.2023.06.006

M3 - Journal article

C2 - 37520020

AN - SCOPUS:85163821560

VL - 4

SP - 463

EP - 465

JO - Heart Rhythm O2

JF - Heart Rhythm O2

SN - 2666-5018

IS - 7

ER -

ID: 366388359