Translation, inter-rater reliability, agreement, and internal consistency of the Spanish version of the cumulated ambulation score in patients after hip fracture

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Translation, inter-rater reliability, agreement, and internal consistency of the Spanish version of the cumulated ambulation score in patients after hip fracture. / Ariza-Vega, Patrocinio; Mora-Traverso, Marta; Ortiz-Piña, Mariana; Ashe, Maureen Celeste; Kristensen, Morten Tange.

In: Disability and Rehabilitation, Vol. 42, No. 19, 2020, p. 2766-2771.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Ariza-Vega, P, Mora-Traverso, M, Ortiz-Piña, M, Ashe, MC & Kristensen, MT 2020, 'Translation, inter-rater reliability, agreement, and internal consistency of the Spanish version of the cumulated ambulation score in patients after hip fracture', Disability and Rehabilitation, vol. 42, no. 19, pp. 2766-2771. https://doi.org/10.1080/09638288.2019.1577499

APA

Ariza-Vega, P., Mora-Traverso, M., Ortiz-Piña, M., Ashe, M. C., & Kristensen, M. T. (2020). Translation, inter-rater reliability, agreement, and internal consistency of the Spanish version of the cumulated ambulation score in patients after hip fracture. Disability and Rehabilitation, 42(19), 2766-2771. https://doi.org/10.1080/09638288.2019.1577499

Vancouver

Ariza-Vega P, Mora-Traverso M, Ortiz-Piña M, Ashe MC, Kristensen MT. Translation, inter-rater reliability, agreement, and internal consistency of the Spanish version of the cumulated ambulation score in patients after hip fracture. Disability and Rehabilitation. 2020;42(19):2766-2771. https://doi.org/10.1080/09638288.2019.1577499

Author

Ariza-Vega, Patrocinio ; Mora-Traverso, Marta ; Ortiz-Piña, Mariana ; Ashe, Maureen Celeste ; Kristensen, Morten Tange. / Translation, inter-rater reliability, agreement, and internal consistency of the Spanish version of the cumulated ambulation score in patients after hip fracture. In: Disability and Rehabilitation. 2020 ; Vol. 42, No. 19. pp. 2766-2771.

Bibtex

@article{bfaedf969e564ad78430385ee3148464,
title = "Translation, inter-rater reliability, agreement, and internal consistency of the Spanish version of the cumulated ambulation score in patients after hip fracture",
abstract = "Purpose: To translate the Cumulated Ambulation Score into Spanish, and to examine its inter-rater reliability, agreement and internal consistency. Materials and Methods: Two occupational therapists independently used the Spanish version of the Cumulated Ambulation Score (three activities scored from 0–2 points) to assess 60 consecutive patients with hip fracture within the first post-surgery week at a traumatology service of a public hospital. We used linear weighted kappa (κ) statistics to determine inter-rater reliability, percent agreement to assess measurement error, Cronbach{\textquoteright}s α coefficient to establish the internal consistency, and the McNemar–Bowker test to evaluate for systematic between-rater differences. Results: The κ was ≥ 0.83 for the three individual activities and the total score, the percent agreement was ≥ 0.87, and Cronbach{\textquoteright}s α was 0.89 with no observed systematic between-rater difference. Conclusions: This study provides evidence for almost perfect inter-rater reliability, excellent internal consistency, and high percent agreement of the Spanish version of the Cumulated Ambulation Score. Due to the strong psychometric properties, and its ease of use, we suggest it be used in Spanish speaking countries to assess early basic mobility status of patients with hip fracture until independence is reached.Implications for rehabilitation The Spanish version of the Cumulated Ambulation Score is a reliable outcome measure to assess basic mobility of patients with hip fracture. We suggest the Spanish version of the Cumulated Ambulation Score be used in Spanish speaking settings to indicate small changes in basic mobility of patients with hip fracture until an independent level is reached. The Spanish version of the Cumulated Ambulation Score can be used with a high reliability by experienced and inexperienced occupational therapists, corresponding to the already established reliability when used by physicians and physiotherapists.",
keywords = "basic mobility, Hip fracture, older adults, psychometric properties, reliability",
author = "Patrocinio Ariza-Vega and Marta Mora-Traverso and Mariana Ortiz-Pi{\~n}a and Ashe, {Maureen Celeste} and Kristensen, {Morten Tange}",
year = "2020",
doi = "10.1080/09638288.2019.1577499",
language = "English",
volume = "42",
pages = "2766--2771",
journal = "Disability and Rehabilitation",
issn = "0963-8288",
publisher = "Taylor & Francis",
number = "19",

}

RIS

TY - JOUR

T1 - Translation, inter-rater reliability, agreement, and internal consistency of the Spanish version of the cumulated ambulation score in patients after hip fracture

AU - Ariza-Vega, Patrocinio

AU - Mora-Traverso, Marta

AU - Ortiz-Piña, Mariana

AU - Ashe, Maureen Celeste

AU - Kristensen, Morten Tange

PY - 2020

Y1 - 2020

N2 - Purpose: To translate the Cumulated Ambulation Score into Spanish, and to examine its inter-rater reliability, agreement and internal consistency. Materials and Methods: Two occupational therapists independently used the Spanish version of the Cumulated Ambulation Score (three activities scored from 0–2 points) to assess 60 consecutive patients with hip fracture within the first post-surgery week at a traumatology service of a public hospital. We used linear weighted kappa (κ) statistics to determine inter-rater reliability, percent agreement to assess measurement error, Cronbach’s α coefficient to establish the internal consistency, and the McNemar–Bowker test to evaluate for systematic between-rater differences. Results: The κ was ≥ 0.83 for the three individual activities and the total score, the percent agreement was ≥ 0.87, and Cronbach’s α was 0.89 with no observed systematic between-rater difference. Conclusions: This study provides evidence for almost perfect inter-rater reliability, excellent internal consistency, and high percent agreement of the Spanish version of the Cumulated Ambulation Score. Due to the strong psychometric properties, and its ease of use, we suggest it be used in Spanish speaking countries to assess early basic mobility status of patients with hip fracture until independence is reached.Implications for rehabilitation The Spanish version of the Cumulated Ambulation Score is a reliable outcome measure to assess basic mobility of patients with hip fracture. We suggest the Spanish version of the Cumulated Ambulation Score be used in Spanish speaking settings to indicate small changes in basic mobility of patients with hip fracture until an independent level is reached. The Spanish version of the Cumulated Ambulation Score can be used with a high reliability by experienced and inexperienced occupational therapists, corresponding to the already established reliability when used by physicians and physiotherapists.

AB - Purpose: To translate the Cumulated Ambulation Score into Spanish, and to examine its inter-rater reliability, agreement and internal consistency. Materials and Methods: Two occupational therapists independently used the Spanish version of the Cumulated Ambulation Score (three activities scored from 0–2 points) to assess 60 consecutive patients with hip fracture within the first post-surgery week at a traumatology service of a public hospital. We used linear weighted kappa (κ) statistics to determine inter-rater reliability, percent agreement to assess measurement error, Cronbach’s α coefficient to establish the internal consistency, and the McNemar–Bowker test to evaluate for systematic between-rater differences. Results: The κ was ≥ 0.83 for the three individual activities and the total score, the percent agreement was ≥ 0.87, and Cronbach’s α was 0.89 with no observed systematic between-rater difference. Conclusions: This study provides evidence for almost perfect inter-rater reliability, excellent internal consistency, and high percent agreement of the Spanish version of the Cumulated Ambulation Score. Due to the strong psychometric properties, and its ease of use, we suggest it be used in Spanish speaking countries to assess early basic mobility status of patients with hip fracture until independence is reached.Implications for rehabilitation The Spanish version of the Cumulated Ambulation Score is a reliable outcome measure to assess basic mobility of patients with hip fracture. We suggest the Spanish version of the Cumulated Ambulation Score be used in Spanish speaking settings to indicate small changes in basic mobility of patients with hip fracture until an independent level is reached. The Spanish version of the Cumulated Ambulation Score can be used with a high reliability by experienced and inexperienced occupational therapists, corresponding to the already established reliability when used by physicians and physiotherapists.

KW - basic mobility

KW - Hip fracture

KW - older adults

KW - psychometric properties

KW - reliability

U2 - 10.1080/09638288.2019.1577499

DO - 10.1080/09638288.2019.1577499

M3 - Journal article

C2 - 30907173

AN - SCOPUS:85063254509

VL - 42

SP - 2766

EP - 2771

JO - Disability and Rehabilitation

JF - Disability and Rehabilitation

SN - 0963-8288

IS - 19

ER -

ID: 261445807