Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients. / Nyholm, Benjamin; Obling, Laust; Hassager, Christian; Grand, Johannes; Møller, Jacob; Othman, Marwan; Kondziella, Daniel; Kjaergaard, Jesper.

In: PLoS ONE, Vol. 17, No. 7 , e0272303, 2022.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Nyholm, B, Obling, L, Hassager, C, Grand, J, Møller, J, Othman, M, Kondziella, D & Kjaergaard, J 2022, 'Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients', PLoS ONE, vol. 17, no. 7 , e0272303. https://doi.org/10.1371/journal.pone.0272303

APA

Nyholm, B., Obling, L., Hassager, C., Grand, J., Møller, J., Othman, M., Kondziella, D., & Kjaergaard, J. (2022). Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients. PLoS ONE, 17(7 ), [e0272303]. https://doi.org/10.1371/journal.pone.0272303

Vancouver

Nyholm B, Obling L, Hassager C, Grand J, Møller J, Othman M et al. Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients. PLoS ONE. 2022;17(7 ). e0272303. https://doi.org/10.1371/journal.pone.0272303

Author

Nyholm, Benjamin ; Obling, Laust ; Hassager, Christian ; Grand, Johannes ; Møller, Jacob ; Othman, Marwan ; Kondziella, Daniel ; Kjaergaard, Jesper. / Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients. In: PLoS ONE. 2022 ; Vol. 17, No. 7 .

Bibtex

@article{4b36e3577ca34ed2a575f34690411854,
title = "Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients",
abstract = "Background Quantitative pupillometry is part of multimodal neuroprognostication of comatose patients after out-of-hospital cardiac arrest (OHCA). However, the reproducibility, repeatability, and reliability of quantitative pupillometry in this setting have not been investigated. Methods In a prospective blinded validation study, we compared manual and quantitative measurements of pupil size. Observer and device variability for all available parameters are expressed as mean difference (bias), limits of agreement (LoA), and reliability expressed as intraclass correlation coefficients (ICC) with a 95% confidence interval. Results Fifty-six unique quadrupled sets of measurement derived from 14 sedated and comatose patients (mean age 70±12 years) were included. For manually measured pupil size, inter-observer bias was -0.14±0.44 mm, LoA of -1.00 to 0.71 mm, and ICC at 0.92 (0.86-0.95). For quantitative pupillometry, we found bias at 0.03±0.17 mm, LoA of -0.31 to 0.36 mm and ICCs at 0.99. Quantitative pupillometry also yielded lower bias and LoA and higher ICC for intra-observer and inter-device measurements. Correlation between manual and automated pupillometry was better in larger pupils, and quantitative pupillometry had less variability and higher ICC, when assessing small pupils. Further, observers failed to detect 26% of the quantitatively estimated abnormal reactivity with manual assessment. We found ICC >0.91 for all quantitative pupillary response parameters (except for latency with ICC 0.81-0.91). Conclusion Automated quantitative pupillometry has excellent reliability and twice the reproducibility and repeatability than manual pupillometry. This study further presents novel estimates of variability for all quantitative pupillary response parameters with excellent reliability. ",
author = "Benjamin Nyholm and Laust Obling and Christian Hassager and Johannes Grand and Jacob M{\o}ller and Marwan Othman and Daniel Kondziella and Jesper Kjaergaard",
note = "Publisher Copyright: {\textcopyright} 2022 Nyholm et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.",
year = "2022",
doi = "10.1371/journal.pone.0272303",
language = "English",
volume = "17",
journal = "PLoS ONE",
issn = "1932-6203",
publisher = "Public Library of Science",
number = "7 ",

}

RIS

TY - JOUR

T1 - Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients

AU - Nyholm, Benjamin

AU - Obling, Laust

AU - Hassager, Christian

AU - Grand, Johannes

AU - Møller, Jacob

AU - Othman, Marwan

AU - Kondziella, Daniel

AU - Kjaergaard, Jesper

N1 - Publisher Copyright: © 2022 Nyholm et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

PY - 2022

Y1 - 2022

N2 - Background Quantitative pupillometry is part of multimodal neuroprognostication of comatose patients after out-of-hospital cardiac arrest (OHCA). However, the reproducibility, repeatability, and reliability of quantitative pupillometry in this setting have not been investigated. Methods In a prospective blinded validation study, we compared manual and quantitative measurements of pupil size. Observer and device variability for all available parameters are expressed as mean difference (bias), limits of agreement (LoA), and reliability expressed as intraclass correlation coefficients (ICC) with a 95% confidence interval. Results Fifty-six unique quadrupled sets of measurement derived from 14 sedated and comatose patients (mean age 70±12 years) were included. For manually measured pupil size, inter-observer bias was -0.14±0.44 mm, LoA of -1.00 to 0.71 mm, and ICC at 0.92 (0.86-0.95). For quantitative pupillometry, we found bias at 0.03±0.17 mm, LoA of -0.31 to 0.36 mm and ICCs at 0.99. Quantitative pupillometry also yielded lower bias and LoA and higher ICC for intra-observer and inter-device measurements. Correlation between manual and automated pupillometry was better in larger pupils, and quantitative pupillometry had less variability and higher ICC, when assessing small pupils. Further, observers failed to detect 26% of the quantitatively estimated abnormal reactivity with manual assessment. We found ICC >0.91 for all quantitative pupillary response parameters (except for latency with ICC 0.81-0.91). Conclusion Automated quantitative pupillometry has excellent reliability and twice the reproducibility and repeatability than manual pupillometry. This study further presents novel estimates of variability for all quantitative pupillary response parameters with excellent reliability.

AB - Background Quantitative pupillometry is part of multimodal neuroprognostication of comatose patients after out-of-hospital cardiac arrest (OHCA). However, the reproducibility, repeatability, and reliability of quantitative pupillometry in this setting have not been investigated. Methods In a prospective blinded validation study, we compared manual and quantitative measurements of pupil size. Observer and device variability for all available parameters are expressed as mean difference (bias), limits of agreement (LoA), and reliability expressed as intraclass correlation coefficients (ICC) with a 95% confidence interval. Results Fifty-six unique quadrupled sets of measurement derived from 14 sedated and comatose patients (mean age 70±12 years) were included. For manually measured pupil size, inter-observer bias was -0.14±0.44 mm, LoA of -1.00 to 0.71 mm, and ICC at 0.92 (0.86-0.95). For quantitative pupillometry, we found bias at 0.03±0.17 mm, LoA of -0.31 to 0.36 mm and ICCs at 0.99. Quantitative pupillometry also yielded lower bias and LoA and higher ICC for intra-observer and inter-device measurements. Correlation between manual and automated pupillometry was better in larger pupils, and quantitative pupillometry had less variability and higher ICC, when assessing small pupils. Further, observers failed to detect 26% of the quantitatively estimated abnormal reactivity with manual assessment. We found ICC >0.91 for all quantitative pupillary response parameters (except for latency with ICC 0.81-0.91). Conclusion Automated quantitative pupillometry has excellent reliability and twice the reproducibility and repeatability than manual pupillometry. This study further presents novel estimates of variability for all quantitative pupillary response parameters with excellent reliability.

U2 - 10.1371/journal.pone.0272303

DO - 10.1371/journal.pone.0272303

M3 - Journal article

C2 - 35901103

AN - SCOPUS:85135003564

VL - 17

JO - PLoS ONE

JF - PLoS ONE

SN - 1932-6203

IS - 7

M1 - e0272303

ER -

ID: 321959533