Standard
Spontaneous baroreflex sensitivity : prospective validation trial of a novel technique in survivors of acute myocardial infarction. / Barthel, Petra; Bauer, Axel; Müller, Alexander; Huster, Katharina M; Kanters, Jørgen K.; Paruchuri, Vijayapraveena; Yang, Xiaoyun; Ulm, Kurt; Malik, Marek; Schmidt, Georg.
In:
Heart rhythm : the official journal of the Heart Rhythm Society, Vol. 9, No. 8, 08.2012, p. 1288-94.
Research output: Contribution to journal › Journal article › Research › peer-review
Harvard
Barthel, P, Bauer, A, Müller, A, Huster, KM
, Kanters, JK, Paruchuri, V, Yang, X, Ulm, K, Malik, M & Schmidt, G 2012, '
Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction',
Heart rhythm : the official journal of the Heart Rhythm Society, vol. 9, no. 8, pp. 1288-94.
https://doi.org/10.1016/j.hrthm.2012.04.017
APA
Barthel, P., Bauer, A., Müller, A., Huster, K. M.
, Kanters, J. K., Paruchuri, V., Yang, X., Ulm, K., Malik, M., & Schmidt, G. (2012).
Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction.
Heart rhythm : the official journal of the Heart Rhythm Society,
9(8), 1288-94.
https://doi.org/10.1016/j.hrthm.2012.04.017
Vancouver
Barthel P, Bauer A, Müller A, Huster KM
, Kanters JK, Paruchuri V et al.
Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction.
Heart rhythm : the official journal of the Heart Rhythm Society. 2012 Aug;9(8):1288-94.
https://doi.org/10.1016/j.hrthm.2012.04.017
Author
Barthel, Petra ; Bauer, Axel ; Müller, Alexander ; Huster, Katharina M ; Kanters, Jørgen K. ; Paruchuri, Vijayapraveena ; Yang, Xiaoyun ; Ulm, Kurt ; Malik, Marek ; Schmidt, Georg. / Spontaneous baroreflex sensitivity : prospective validation trial of a novel technique in survivors of acute myocardial infarction. In: Heart rhythm : the official journal of the Heart Rhythm Society. 2012 ; Vol. 9, No. 8. pp. 1288-94.
Bibtex
@article{a05f9e691d984397a75dbce91a33422c,
title = "Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction",
abstract = "Low baroreflex sensitivity (BRS) indicates poor prognosis after acute myocardial infarction. Noninvasive BRS assessment is complicated by nonstationarities and noise in electrocardiogram and pressure signals. Phase-rectified signal averaging is a novel signal processing technology overcoming these problems.",
keywords = "Aged, Baroreflex, Blood Pressure, Diabetic Angiopathies, Electrocardiography, Female, Humans, Male, Middle Aged, Multivariate Analysis, Myocardial Infarction, Patient Selection, Prospective Studies, ROC Curve, Signal Processing, Computer-Assisted",
author = "Petra Barthel and Axel Bauer and Alexander M{\"u}ller and Huster, {Katharina M} and Kanters, {J{\o}rgen K.} and Vijayapraveena Paruchuri and Xiaoyun Yang and Kurt Ulm and Marek Malik and Georg Schmidt",
note = "Copyright {\textcopyright} 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.",
year = "2012",
month = aug,
doi = "10.1016/j.hrthm.2012.04.017",
language = "English",
volume = "9",
pages = "1288--94",
journal = "Heart Rhythm",
issn = "1547-5271",
publisher = "Elsevier",
number = "8",
}
RIS
TY - JOUR
T1 - Spontaneous baroreflex sensitivity
T2 - prospective validation trial of a novel technique in survivors of acute myocardial infarction
AU - Barthel, Petra
AU - Bauer, Axel
AU - Müller, Alexander
AU - Huster, Katharina M
AU - Kanters, Jørgen K.
AU - Paruchuri, Vijayapraveena
AU - Yang, Xiaoyun
AU - Ulm, Kurt
AU - Malik, Marek
AU - Schmidt, Georg
N1 - Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
PY - 2012/8
Y1 - 2012/8
N2 - Low baroreflex sensitivity (BRS) indicates poor prognosis after acute myocardial infarction. Noninvasive BRS assessment is complicated by nonstationarities and noise in electrocardiogram and pressure signals. Phase-rectified signal averaging is a novel signal processing technology overcoming these problems.
AB - Low baroreflex sensitivity (BRS) indicates poor prognosis after acute myocardial infarction. Noninvasive BRS assessment is complicated by nonstationarities and noise in electrocardiogram and pressure signals. Phase-rectified signal averaging is a novel signal processing technology overcoming these problems.
KW - Aged
KW - Baroreflex
KW - Blood Pressure
KW - Diabetic Angiopathies
KW - Electrocardiography
KW - Female
KW - Humans
KW - Male
KW - Middle Aged
KW - Multivariate Analysis
KW - Myocardial Infarction
KW - Patient Selection
KW - Prospective Studies
KW - ROC Curve
KW - Signal Processing, Computer-Assisted
U2 - 10.1016/j.hrthm.2012.04.017
DO - 10.1016/j.hrthm.2012.04.017
M3 - Journal article
C2 - 22516186
VL - 9
SP - 1288
EP - 1294
JO - Heart Rhythm
JF - Heart Rhythm
SN - 1547-5271
IS - 8
ER -