Predictive Performance of the Simplified Acute Physiology Score (SAPS) II and the Initial Sequential Organ Failure Assessment (SOFA) Score in Acutely Ill Intensive Care Patients: Post-Hoc Analyses of the SUP-ICU Inception Cohort Study

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Predictive Performance of the Simplified Acute Physiology Score (SAPS) II and the Initial Sequential Organ Failure Assessment (SOFA) Score in Acutely Ill Intensive Care Patients : Post-Hoc Analyses of the SUP-ICU Inception Cohort Study. / Granholm, Anders; Møller, Morten Hylander; Kragh, Mette; Perner, Anders; Hjortrup, Peter Buhl.

In: PLOS ONE, Vol. 11, No. 12, e0168948, 2016, p. 1-15.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Granholm, A, Møller, MH, Kragh, M, Perner, A & Hjortrup, PB 2016, 'Predictive Performance of the Simplified Acute Physiology Score (SAPS) II and the Initial Sequential Organ Failure Assessment (SOFA) Score in Acutely Ill Intensive Care Patients: Post-Hoc Analyses of the SUP-ICU Inception Cohort Study', PLOS ONE, vol. 11, no. 12, e0168948, pp. 1-15. https://doi.org/10.1371/journal.pone.0168948

APA

Granholm, A., Møller, M. H., Kragh, M., Perner, A., & Hjortrup, P. B. (2016). Predictive Performance of the Simplified Acute Physiology Score (SAPS) II and the Initial Sequential Organ Failure Assessment (SOFA) Score in Acutely Ill Intensive Care Patients: Post-Hoc Analyses of the SUP-ICU Inception Cohort Study. PLOS ONE, 11(12), 1-15. [e0168948]. https://doi.org/10.1371/journal.pone.0168948

Vancouver

Granholm A, Møller MH, Kragh M, Perner A, Hjortrup PB. Predictive Performance of the Simplified Acute Physiology Score (SAPS) II and the Initial Sequential Organ Failure Assessment (SOFA) Score in Acutely Ill Intensive Care Patients: Post-Hoc Analyses of the SUP-ICU Inception Cohort Study. PLOS ONE. 2016;11(12):1-15. e0168948. https://doi.org/10.1371/journal.pone.0168948

Author

Granholm, Anders ; Møller, Morten Hylander ; Kragh, Mette ; Perner, Anders ; Hjortrup, Peter Buhl. / Predictive Performance of the Simplified Acute Physiology Score (SAPS) II and the Initial Sequential Organ Failure Assessment (SOFA) Score in Acutely Ill Intensive Care Patients : Post-Hoc Analyses of the SUP-ICU Inception Cohort Study. In: PLOS ONE. 2016 ; Vol. 11, No. 12. pp. 1-15.

Bibtex

@article{db4b2c19ec344844a999901e486bf1e9,
title = "Predictive Performance of the Simplified Acute Physiology Score (SAPS) II and the Initial Sequential Organ Failure Assessment (SOFA) Score in Acutely Ill Intensive Care Patients: Post-Hoc Analyses of the SUP-ICU Inception Cohort Study",
abstract = "PURPOSE: Severity scores including the Simplified Acute Physiology Score (SAPS) II and the Sequential Organ Failure Assessment (SOFA) score are used in intensive care units (ICUs) to assess disease severity, predict mortality and in research. We aimed to assess the predictive performance of SAPS II and the initial SOFA score for in-hospital and 90-day mortality in a contemporary international cohort.METHODS: This was a post-hoc study of the Stress Ulcer Prophylaxis in the Intensive Care Unit (SUP-ICU) inception cohort study, which included acutely ill adults from ICUs across 11 countries (n = 1034). We compared the discrimination of SAPS II and initial SOFA scores, compared the discrimination of SAPS II in our cohort with the original cohort, assessed the calibration of SAPS II customised to our cohort, and compared the discrimination for 90-day mortality vs. in-hospital mortality for both scores. Discrimination was evaluated using areas under the receiver operating characteristics curves (AUROC). Calibration was evaluated using Hosmer-Lemeshow's goodness-of-fit Ĉ-statistic.RESULTS: AUROC for in-hospital mortality was 0.80 (95% confidence interval (CI) 0.77-0.83) for SAPS II and 0.73 (95% CI 0.69-0.76) for initial SOFA score (P<0.001 for the comparison). Calibration of the customised SAPS II for predicting in-hospital mortality was adequate (P = 0.60). Discrimination of SAPS II was reduced compared with the original SAPS II validation sample (AUROC 0.80 vs. 0.86; P = 0.001). AUROC for 90-day mortality was 0.79 (95% CI 0.76-0.82; P = 0.74 for comparison with in-hospital mortality) for SAPS II and 0.71 (95% CI 0.68-0.75; P = 0.66 for comparison with in-hospital mortality) for the initial SOFA score.CONCLUSIONS: The predictive performance of SAPS II was similar for in-hospital and 90-day mortality and superior to that of the initial SOFA score, but SAPS II's performance has decreased over time. Use of a contemporary severity score with improved predictive performance may be of value.",
keywords = "Journal Article",
author = "Anders Granholm and M{\o}ller, {Morten Hylander} and Mette Kragh and Anders Perner and Hjortrup, {Peter Buhl}",
year = "2016",
doi = "10.1371/journal.pone.0168948",
language = "English",
volume = "11",
pages = "1--15",
journal = "PLoS ONE",
issn = "1932-6203",
publisher = "Public Library of Science",
number = "12",

}

RIS

TY - JOUR

T1 - Predictive Performance of the Simplified Acute Physiology Score (SAPS) II and the Initial Sequential Organ Failure Assessment (SOFA) Score in Acutely Ill Intensive Care Patients

T2 - Post-Hoc Analyses of the SUP-ICU Inception Cohort Study

AU - Granholm, Anders

AU - Møller, Morten Hylander

AU - Kragh, Mette

AU - Perner, Anders

AU - Hjortrup, Peter Buhl

PY - 2016

Y1 - 2016

N2 - PURPOSE: Severity scores including the Simplified Acute Physiology Score (SAPS) II and the Sequential Organ Failure Assessment (SOFA) score are used in intensive care units (ICUs) to assess disease severity, predict mortality and in research. We aimed to assess the predictive performance of SAPS II and the initial SOFA score for in-hospital and 90-day mortality in a contemporary international cohort.METHODS: This was a post-hoc study of the Stress Ulcer Prophylaxis in the Intensive Care Unit (SUP-ICU) inception cohort study, which included acutely ill adults from ICUs across 11 countries (n = 1034). We compared the discrimination of SAPS II and initial SOFA scores, compared the discrimination of SAPS II in our cohort with the original cohort, assessed the calibration of SAPS II customised to our cohort, and compared the discrimination for 90-day mortality vs. in-hospital mortality for both scores. Discrimination was evaluated using areas under the receiver operating characteristics curves (AUROC). Calibration was evaluated using Hosmer-Lemeshow's goodness-of-fit Ĉ-statistic.RESULTS: AUROC for in-hospital mortality was 0.80 (95% confidence interval (CI) 0.77-0.83) for SAPS II and 0.73 (95% CI 0.69-0.76) for initial SOFA score (P<0.001 for the comparison). Calibration of the customised SAPS II for predicting in-hospital mortality was adequate (P = 0.60). Discrimination of SAPS II was reduced compared with the original SAPS II validation sample (AUROC 0.80 vs. 0.86; P = 0.001). AUROC for 90-day mortality was 0.79 (95% CI 0.76-0.82; P = 0.74 for comparison with in-hospital mortality) for SAPS II and 0.71 (95% CI 0.68-0.75; P = 0.66 for comparison with in-hospital mortality) for the initial SOFA score.CONCLUSIONS: The predictive performance of SAPS II was similar for in-hospital and 90-day mortality and superior to that of the initial SOFA score, but SAPS II's performance has decreased over time. Use of a contemporary severity score with improved predictive performance may be of value.

AB - PURPOSE: Severity scores including the Simplified Acute Physiology Score (SAPS) II and the Sequential Organ Failure Assessment (SOFA) score are used in intensive care units (ICUs) to assess disease severity, predict mortality and in research. We aimed to assess the predictive performance of SAPS II and the initial SOFA score for in-hospital and 90-day mortality in a contemporary international cohort.METHODS: This was a post-hoc study of the Stress Ulcer Prophylaxis in the Intensive Care Unit (SUP-ICU) inception cohort study, which included acutely ill adults from ICUs across 11 countries (n = 1034). We compared the discrimination of SAPS II and initial SOFA scores, compared the discrimination of SAPS II in our cohort with the original cohort, assessed the calibration of SAPS II customised to our cohort, and compared the discrimination for 90-day mortality vs. in-hospital mortality for both scores. Discrimination was evaluated using areas under the receiver operating characteristics curves (AUROC). Calibration was evaluated using Hosmer-Lemeshow's goodness-of-fit Ĉ-statistic.RESULTS: AUROC for in-hospital mortality was 0.80 (95% confidence interval (CI) 0.77-0.83) for SAPS II and 0.73 (95% CI 0.69-0.76) for initial SOFA score (P<0.001 for the comparison). Calibration of the customised SAPS II for predicting in-hospital mortality was adequate (P = 0.60). Discrimination of SAPS II was reduced compared with the original SAPS II validation sample (AUROC 0.80 vs. 0.86; P = 0.001). AUROC for 90-day mortality was 0.79 (95% CI 0.76-0.82; P = 0.74 for comparison with in-hospital mortality) for SAPS II and 0.71 (95% CI 0.68-0.75; P = 0.66 for comparison with in-hospital mortality) for the initial SOFA score.CONCLUSIONS: The predictive performance of SAPS II was similar for in-hospital and 90-day mortality and superior to that of the initial SOFA score, but SAPS II's performance has decreased over time. Use of a contemporary severity score with improved predictive performance may be of value.

KW - Journal Article

U2 - 10.1371/journal.pone.0168948

DO - 10.1371/journal.pone.0168948

M3 - Journal article

C2 - 28006826

VL - 11

SP - 1

EP - 15

JO - PLoS ONE

JF - PLoS ONE

SN - 1932-6203

IS - 12

M1 - e0168948

ER -

ID: 177436924