Metal-metal-hofteproteser

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Metal-metal-hofteproteser. / Ulrich, Michael; Overgaard, Søren; Penny, Jeannette.

In: Ugeskrift for Laeger, Vol. 176, No. 34, 2014, p. 1572-1576.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Ulrich, M, Overgaard, S & Penny, J 2014, 'Metal-metal-hofteproteser', Ugeskrift for Laeger, vol. 176, no. 34, pp. 1572-1576.

APA

Ulrich, M., Overgaard, S., & Penny, J. (2014). Metal-metal-hofteproteser. Ugeskrift for Laeger, 176(34), 1572-1576.

Vancouver

Ulrich M, Overgaard S, Penny J. Metal-metal-hofteproteser. Ugeskrift for Laeger. 2014;176(34):1572-1576.

Author

Ulrich, Michael ; Overgaard, Søren ; Penny, Jeannette. / Metal-metal-hofteproteser. In: Ugeskrift for Laeger. 2014 ; Vol. 176, No. 34. pp. 1572-1576.

Bibtex

@article{b3a8d9b0c74f445499b1e46920957bf0,
title = "Metal-metal-hofteproteser",
abstract = "In Denmark 4,456 metal-on-metal (MoM) hip prostheses have been implanted. Evidence demonstrates that some patients develope adverse biological reactions causing failures of MoM hip arthroplasty. Some reactions might be systemic. Failure rates are associated with the type and the design of the MoM hip implant. A Danish surveillance programme has been initiated addressing these problems.",
author = "Michael Ulrich and S{\o}ren Overgaard and Jeannette Penny",
year = "2014",
language = "Dansk",
volume = "176",
pages = "1572--1576",
journal = "Ugeskrift for Laeger",
issn = "0041-5782",
publisher = "Almindelige Danske Laegeforening",
number = "34",

}

RIS

TY - JOUR

T1 - Metal-metal-hofteproteser

AU - Ulrich, Michael

AU - Overgaard, Søren

AU - Penny, Jeannette

PY - 2014

Y1 - 2014

N2 - In Denmark 4,456 metal-on-metal (MoM) hip prostheses have been implanted. Evidence demonstrates that some patients develope adverse biological reactions causing failures of MoM hip arthroplasty. Some reactions might be systemic. Failure rates are associated with the type and the design of the MoM hip implant. A Danish surveillance programme has been initiated addressing these problems.

AB - In Denmark 4,456 metal-on-metal (MoM) hip prostheses have been implanted. Evidence demonstrates that some patients develope adverse biological reactions causing failures of MoM hip arthroplasty. Some reactions might be systemic. Failure rates are associated with the type and the design of the MoM hip implant. A Danish surveillance programme has been initiated addressing these problems.

M3 - Tidsskriftartikel

C2 - 25293565

VL - 176

SP - 1572

EP - 1576

JO - Ugeskrift for Laeger

JF - Ugeskrift for Laeger

SN - 0041-5782

IS - 34

ER -

ID: 252051923