A reference compound for 199mHg perturbed angular correlation of γ-rays spectroscopy
Research output: Contribution to journal › Journal article › Research › peer-review
Standard
A reference compound for 199mHg perturbed angular correlation of γ-rays spectroscopy. / Jancsó, Attila; Correia, Joao G.; Balogh, Ria K.; Schell, Juliana; Jensen, Marianne L.; Szunyogh, Daniel; Thulstrup, Peter W.; Hemmingsen, Lars.
In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 1002, 165154, 21.06.2021.Research output: Contribution to journal › Journal article › Research › peer-review
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - A reference compound for 199mHg perturbed angular correlation of γ-rays spectroscopy
AU - Jancsó, Attila
AU - Correia, Joao G.
AU - Balogh, Ria K.
AU - Schell, Juliana
AU - Jensen, Marianne L.
AU - Szunyogh, Daniel
AU - Thulstrup, Peter W.
AU - Hemmingsen, Lars
PY - 2021/6/21
Y1 - 2021/6/21
N2 - 199mHg is a very useful probe for perturbed angular correlation of γ-rays (PAC) spectroscopy. Here we present 199mHg PAC data for a Hg2+ containing compound, Hg(Cys)2(s), giving one unique nuclear quadrupole interaction (NQI). Four separate sample preparations were carried out, and measured on analogue and digital PAC setups, leading to the following reference data: νQ=1.458(7) GHz and η=0.10(6). The compound may be applied as an easy-to-synthesize reference sample, providing fast control of the effective anisotropy and time calibration of PAC instruments to be used for 199mHg PAC experiments.
AB - 199mHg is a very useful probe for perturbed angular correlation of γ-rays (PAC) spectroscopy. Here we present 199mHg PAC data for a Hg2+ containing compound, Hg(Cys)2(s), giving one unique nuclear quadrupole interaction (NQI). Four separate sample preparations were carried out, and measured on analogue and digital PAC setups, leading to the following reference data: νQ=1.458(7) GHz and η=0.10(6). The compound may be applied as an easy-to-synthesize reference sample, providing fast control of the effective anisotropy and time calibration of PAC instruments to be used for 199mHg PAC experiments.
KW - Hg
KW - Mercury
KW - Perturbed angular correlation (PAC) spectroscopy
KW - Reference compound
U2 - 10.1016/j.nima.2021.165154
DO - 10.1016/j.nima.2021.165154
M3 - Journal article
AN - SCOPUS:85104283470
VL - 1002
JO - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
SN - 0168-9002
M1 - 165154
ER -
ID: 261059446