Test-retest repeatability and interobserver variation of healthy tissue metabolism using F-18-FDG PET/CT of the thorax among lung cancer patients
Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Standard
Test-retest repeatability and interobserver variation of healthy tissue metabolism using F-18-FDG PET/CT of the thorax among lung cancer patients. / Malaih, Afnan A.; Dunn, Joel T.; Nygard, Lotte; Kovacs, David G.; Andersen, Flemming L.; Barrington, Sally F.; Fischer, Barbara M.
I: Nuclear Medicine Communications, Bind 43, Nr. 5, 05.2022, s. 549-559.Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Test-retest repeatability and interobserver variation of healthy tissue metabolism using F-18-FDG PET/CT of the thorax among lung cancer patients
AU - Malaih, Afnan A.
AU - Dunn, Joel T.
AU - Nygard, Lotte
AU - Kovacs, David G.
AU - Andersen, Flemming L.
AU - Barrington, Sally F.
AU - Fischer, Barbara M.
PY - 2022/5
Y1 - 2022/5
N2 - Objectives The aim of this study was to assess the test-retest repeatability and interobserver variation in healthy tissue (HT) metabolism using 2-deoxy-2-[F-18]fluoro-d-glucose (F-18-FDG) PET/computed tomography (PET/CT) of the thorax in lung cancer patients. Methods A retrospective analysis was conducted in 22 patients with non-small cell lung cancer who had two PET/CT scans of the thorax performed 3 days apart with no interval treatment. The maximum, mean and peak standardized uptake values (SUVs) in different HTs were measured by a single observer for the test-retest analysis and two observers for interobserver variation. Bland-Altman plots were used to assess the repeatability and interobserver variation. Intrasubject variability was evaluated using within-subject coefficients of variation (wCV). Results The wCV of test-retest SUVmean measurements in mediastinal blood pool, bone marrow, skeletal muscles and lungs was less than 20%. The left ventricle (LV) showed higher wCV (>60%) in all SUV parameters with wide limits of repeatability. High interobserver agreement was found with wCV of less than 10% in SUVmean of all HT, but up to 22% was noted in the LV. Conclusion HT metabolism is stable in a test-retest scenario and has high interobserver agreement. SUVmean was the most stable metric in organs with low FDG uptake and SUVpeak in HTs with moderate uptake. Test-retest measurements in LV were highly variable irrespective of the SUV parameters used for measurements.
AB - Objectives The aim of this study was to assess the test-retest repeatability and interobserver variation in healthy tissue (HT) metabolism using 2-deoxy-2-[F-18]fluoro-d-glucose (F-18-FDG) PET/computed tomography (PET/CT) of the thorax in lung cancer patients. Methods A retrospective analysis was conducted in 22 patients with non-small cell lung cancer who had two PET/CT scans of the thorax performed 3 days apart with no interval treatment. The maximum, mean and peak standardized uptake values (SUVs) in different HTs were measured by a single observer for the test-retest analysis and two observers for interobserver variation. Bland-Altman plots were used to assess the repeatability and interobserver variation. Intrasubject variability was evaluated using within-subject coefficients of variation (wCV). Results The wCV of test-retest SUVmean measurements in mediastinal blood pool, bone marrow, skeletal muscles and lungs was less than 20%. The left ventricle (LV) showed higher wCV (>60%) in all SUV parameters with wide limits of repeatability. High interobserver agreement was found with wCV of less than 10% in SUVmean of all HT, but up to 22% was noted in the LV. Conclusion HT metabolism is stable in a test-retest scenario and has high interobserver agreement. SUVmean was the most stable metric in organs with low FDG uptake and SUVpeak in HTs with moderate uptake. Test-retest measurements in LV were highly variable irrespective of the SUV parameters used for measurements.
KW - 2-deoxy-2-[F-18]fluoro-d-glucose
KW - healthy tissues
KW - interobserver variation
KW - PET-computed tomography
KW - repeatability
KW - standardized uptake value
KW - thorax
KW - POSITRON-EMISSION-TOMOGRAPHY
KW - STANDARDIZED UPTAKE VALUES
KW - INTERREADER AGREEMENT
KW - MYOCARDIAL-METABOLISM
KW - FDG UPTAKE
KW - VARIABILITY
KW - TUMOR
KW - SUV
KW - LIVER
KW - REPRODUCIBILITY
U2 - 10.1097/MNM.0000000000001537
DO - 10.1097/MNM.0000000000001537
M3 - Journal article
C2 - 35081091
VL - 43
SP - 549
EP - 559
JO - Nuclear Medicine Communications
JF - Nuclear Medicine Communications
SN - 0143-3636
IS - 5
ER -
ID: 315261169