State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder. / De Backer, Ole; Hafiz, Hussein; Fabre, Aurelie; Lertsapcharoen, Pornthep; Srimahachota, Suphot; Foley, David; Sondergaard, Lars.

I: Catheterization and Cardiovascular Interventions, Bind 97, Nr. 7, 2021, s. E1011–E1018.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

De Backer, O, Hafiz, H, Fabre, A, Lertsapcharoen, P, Srimahachota, S, Foley, D & Sondergaard, L 2021, 'State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder', Catheterization and Cardiovascular Interventions, bind 97, nr. 7, s. E1011–E1018. https://doi.org/10.1002/ccd.29331

APA

De Backer, O., Hafiz, H., Fabre, A., Lertsapcharoen, P., Srimahachota, S., Foley, D., & Sondergaard, L. (2021). State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder. Catheterization and Cardiovascular Interventions, 97(7), E1011–E1018. https://doi.org/10.1002/ccd.29331

Vancouver

De Backer O, Hafiz H, Fabre A, Lertsapcharoen P, Srimahachota S, Foley D o.a. State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder. Catheterization and Cardiovascular Interventions. 2021;97(7):E1011–E1018. https://doi.org/10.1002/ccd.29331

Author

De Backer, Ole ; Hafiz, Hussein ; Fabre, Aurelie ; Lertsapcharoen, Pornthep ; Srimahachota, Suphot ; Foley, David ; Sondergaard, Lars. / State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder. I: Catheterization and Cardiovascular Interventions. 2021 ; Bind 97, Nr. 7. s. E1011–E1018.

Bibtex

@article{0565105655404cecb2a2de5e11ee6cfe,
title = "State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder",
abstract = "ObjectivesThis study aimed to present a new approach of thorough preclinical testing of a novel left atrial appendage (LAA) occluder device.BackgroundThe development of a safe and effective LAA occluder has been shown to be challenging.MethodsThe novel OMEGATM LAA occluder (Eclipse Medical, Ireland) was tested in a porcine model and three-dimensional (3D) human LAA models – this as a prelude to its first-in-human use.ResultsIn a first series of in-vivo experiments, the OMEGATM LAA occluder was shown to have a satisfactory device biocompatibility in a porcine model. The design of the OMEGATM device was further refined and optimized following three more series of in-vivo experiments. The second generation OMEGATM device was designed with thinner wires, leading to a profile reduction. Based on in-vitro testing of different OMEGATM device sizes implanted at different depths in human three-dimensional (3D) LAA models, it could be determined that (1) the landing zone should be measured at a median depth of 12 mm from the LAA ostium; (2) the distal self-retaining inverted cup should have 10%-25% compression to minimize device embolization risk; and (3) the disc should be slightly inverted, i.e. pulled into the LAA, to promote complete LAA occlusion. The combined in-vivo and in-vitro testing resulted in an optimized pre-procedural planning of the first-in-human case treated with the OMEGATM device.ConclusionsThis series of carefully planned in-vivo and in-vitro experiments allowed demonstration of the safety and efficacy of the OMEGATM LAA occluder. This approach of thorough preclinical testing of medical devices may reduce the risk of complications in first-in-human cases and may become the standard approach for device development and preclinical testing in the future.",
author = "{De Backer}, Ole and Hussein Hafiz and Aurelie Fabre and Pornthep Lertsapcharoen and Suphot Srimahachota and David Foley and Lars Sondergaard",
year = "2021",
doi = "10.1002/ccd.29331",
language = "English",
volume = "97",
pages = "E1011–E1018",
journal = "Catheterization and Cardiovascular Interventions",
issn = "1522-1946",
publisher = "JohnWiley & Sons, Inc.",
number = "7",

}

RIS

TY - JOUR

T1 - State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder

AU - De Backer, Ole

AU - Hafiz, Hussein

AU - Fabre, Aurelie

AU - Lertsapcharoen, Pornthep

AU - Srimahachota, Suphot

AU - Foley, David

AU - Sondergaard, Lars

PY - 2021

Y1 - 2021

N2 - ObjectivesThis study aimed to present a new approach of thorough preclinical testing of a novel left atrial appendage (LAA) occluder device.BackgroundThe development of a safe and effective LAA occluder has been shown to be challenging.MethodsThe novel OMEGATM LAA occluder (Eclipse Medical, Ireland) was tested in a porcine model and three-dimensional (3D) human LAA models – this as a prelude to its first-in-human use.ResultsIn a first series of in-vivo experiments, the OMEGATM LAA occluder was shown to have a satisfactory device biocompatibility in a porcine model. The design of the OMEGATM device was further refined and optimized following three more series of in-vivo experiments. The second generation OMEGATM device was designed with thinner wires, leading to a profile reduction. Based on in-vitro testing of different OMEGATM device sizes implanted at different depths in human three-dimensional (3D) LAA models, it could be determined that (1) the landing zone should be measured at a median depth of 12 mm from the LAA ostium; (2) the distal self-retaining inverted cup should have 10%-25% compression to minimize device embolization risk; and (3) the disc should be slightly inverted, i.e. pulled into the LAA, to promote complete LAA occlusion. The combined in-vivo and in-vitro testing resulted in an optimized pre-procedural planning of the first-in-human case treated with the OMEGATM device.ConclusionsThis series of carefully planned in-vivo and in-vitro experiments allowed demonstration of the safety and efficacy of the OMEGATM LAA occluder. This approach of thorough preclinical testing of medical devices may reduce the risk of complications in first-in-human cases and may become the standard approach for device development and preclinical testing in the future.

AB - ObjectivesThis study aimed to present a new approach of thorough preclinical testing of a novel left atrial appendage (LAA) occluder device.BackgroundThe development of a safe and effective LAA occluder has been shown to be challenging.MethodsThe novel OMEGATM LAA occluder (Eclipse Medical, Ireland) was tested in a porcine model and three-dimensional (3D) human LAA models – this as a prelude to its first-in-human use.ResultsIn a first series of in-vivo experiments, the OMEGATM LAA occluder was shown to have a satisfactory device biocompatibility in a porcine model. The design of the OMEGATM device was further refined and optimized following three more series of in-vivo experiments. The second generation OMEGATM device was designed with thinner wires, leading to a profile reduction. Based on in-vitro testing of different OMEGATM device sizes implanted at different depths in human three-dimensional (3D) LAA models, it could be determined that (1) the landing zone should be measured at a median depth of 12 mm from the LAA ostium; (2) the distal self-retaining inverted cup should have 10%-25% compression to minimize device embolization risk; and (3) the disc should be slightly inverted, i.e. pulled into the LAA, to promote complete LAA occlusion. The combined in-vivo and in-vitro testing resulted in an optimized pre-procedural planning of the first-in-human case treated with the OMEGATM device.ConclusionsThis series of carefully planned in-vivo and in-vitro experiments allowed demonstration of the safety and efficacy of the OMEGATM LAA occluder. This approach of thorough preclinical testing of medical devices may reduce the risk of complications in first-in-human cases and may become the standard approach for device development and preclinical testing in the future.

U2 - 10.1002/ccd.29331

DO - 10.1002/ccd.29331

M3 - Journal article

C2 - 33034944

VL - 97

SP - E1011–E1018

JO - Catheterization and Cardiovascular Interventions

JF - Catheterization and Cardiovascular Interventions

SN - 1522-1946

IS - 7

ER -

ID: 284097408