Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI. / Kjaer, Andreas; Lebech, Anne-Mette; Hesse, Birger; Petersen, Claus Leth.

I: Clinical Physiology and Functional Imaging, Bind 25, Nr. 6, 2005, s. 344-9.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Kjaer, A, Lebech, A-M, Hesse, B & Petersen, CL 2005, 'Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI.', Clinical Physiology and Functional Imaging, bind 25, nr. 6, s. 344-9. https://doi.org/10.1111/j.1475-097X.2005.00635.x

APA

Kjaer, A., Lebech, A-M., Hesse, B., & Petersen, C. L. (2005). Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI. Clinical Physiology and Functional Imaging, 25(6), 344-9. https://doi.org/10.1111/j.1475-097X.2005.00635.x

Vancouver

Kjaer A, Lebech A-M, Hesse B, Petersen CL. Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI. Clinical Physiology and Functional Imaging. 2005;25(6):344-9. https://doi.org/10.1111/j.1475-097X.2005.00635.x

Author

Kjaer, Andreas ; Lebech, Anne-Mette ; Hesse, Birger ; Petersen, Claus Leth. / Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI. I: Clinical Physiology and Functional Imaging. 2005 ; Bind 25, Nr. 6. s. 344-9.

Bibtex

@article{972e25c0accd11ddb538000ea68e967b,
title = "Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI.",
abstract = "BACKGROUND: Right ventricular (RV) function is of interest in an array of cardiopulmonary diseases. First-pass radionuclide ventriculography (FP), gated blood-pool single photon emission tomography (GBPS) and cardiac magnetic resonance imaging (MRI) are three currently used non-invasive methods for evaluation of right-sided cardiac function. The aim of our study was to compare the agreement between these methods when measuring right-sided cardiac function. METHODS: Twenty-four healthy volunteers were included. Mean age was 44 years (range: 25-60) and 29% were females. All participants had FP, GBPS and breath-hold cine MRI performed according to standard protocols. RESULTS: Normal ranges for RV ejection fraction (RVEF) defined as mean +/- 2SD were 0.49-0.72, 0.44-0.66 and 0.40-0.69 when measured by MRI, FP and GBPS respectively. Bland-Altman analysis showed a mean difference (bias) between MRI and FP of 0.05 (95% CI: 0.03-0.08) and of 0.06 (95% CI: 0.02-0.10) between MRI and GBPS. No systematic bias was found between FP and GBPS. Normal values for RV end-diastolic volume index (RVEDVI) were 37-95 and 29-91 ml m(-2) when measured by MRI and GBPS respectively. The mean difference between RVEDVI was 6 ml m(-2) (95% CI: 0-11). CONCLUSIONS: (i) Normal values of RVEF differ between MRI, FP and GBPS with wide limits of agreement, accordingly it is difficult to evaluate changes over time if measured by different methods, (ii) RV volumes are in the same range when measured by MRI or GBPS but with wide limits of agreement, and (iii) if MRI is considered gold standard then FP is more accurate than GBPS for RVEF measurements.",
author = "Andreas Kjaer and Anne-Mette Lebech and Birger Hesse and Petersen, {Claus Leth}",
note = "Keywords: Adult; Female; Gated Blood-Pool Imaging; Heart Ventricles; Humans; Image Interpretation, Computer-Assisted; Magnetic Resonance Imaging, Cine; Male; Reproducibility of Results; Sensitivity and Specificity; Stroke Volume; Tomography, Emission-Computed, Single-Photon; Ventricular Function, Right; Ventriculography, First-Pass",
year = "2005",
doi = "10.1111/j.1475-097X.2005.00635.x",
language = "English",
volume = "25",
pages = "344--9",
journal = "Clinical Physiology and Functional Imaging",
issn = "1475-0961",
publisher = "Wiley-Blackwell",
number = "6",

}

RIS

TY - JOUR

T1 - Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI.

AU - Kjaer, Andreas

AU - Lebech, Anne-Mette

AU - Hesse, Birger

AU - Petersen, Claus Leth

N1 - Keywords: Adult; Female; Gated Blood-Pool Imaging; Heart Ventricles; Humans; Image Interpretation, Computer-Assisted; Magnetic Resonance Imaging, Cine; Male; Reproducibility of Results; Sensitivity and Specificity; Stroke Volume; Tomography, Emission-Computed, Single-Photon; Ventricular Function, Right; Ventriculography, First-Pass

PY - 2005

Y1 - 2005

N2 - BACKGROUND: Right ventricular (RV) function is of interest in an array of cardiopulmonary diseases. First-pass radionuclide ventriculography (FP), gated blood-pool single photon emission tomography (GBPS) and cardiac magnetic resonance imaging (MRI) are three currently used non-invasive methods for evaluation of right-sided cardiac function. The aim of our study was to compare the agreement between these methods when measuring right-sided cardiac function. METHODS: Twenty-four healthy volunteers were included. Mean age was 44 years (range: 25-60) and 29% were females. All participants had FP, GBPS and breath-hold cine MRI performed according to standard protocols. RESULTS: Normal ranges for RV ejection fraction (RVEF) defined as mean +/- 2SD were 0.49-0.72, 0.44-0.66 and 0.40-0.69 when measured by MRI, FP and GBPS respectively. Bland-Altman analysis showed a mean difference (bias) between MRI and FP of 0.05 (95% CI: 0.03-0.08) and of 0.06 (95% CI: 0.02-0.10) between MRI and GBPS. No systematic bias was found between FP and GBPS. Normal values for RV end-diastolic volume index (RVEDVI) were 37-95 and 29-91 ml m(-2) when measured by MRI and GBPS respectively. The mean difference between RVEDVI was 6 ml m(-2) (95% CI: 0-11). CONCLUSIONS: (i) Normal values of RVEF differ between MRI, FP and GBPS with wide limits of agreement, accordingly it is difficult to evaluate changes over time if measured by different methods, (ii) RV volumes are in the same range when measured by MRI or GBPS but with wide limits of agreement, and (iii) if MRI is considered gold standard then FP is more accurate than GBPS for RVEF measurements.

AB - BACKGROUND: Right ventricular (RV) function is of interest in an array of cardiopulmonary diseases. First-pass radionuclide ventriculography (FP), gated blood-pool single photon emission tomography (GBPS) and cardiac magnetic resonance imaging (MRI) are three currently used non-invasive methods for evaluation of right-sided cardiac function. The aim of our study was to compare the agreement between these methods when measuring right-sided cardiac function. METHODS: Twenty-four healthy volunteers were included. Mean age was 44 years (range: 25-60) and 29% were females. All participants had FP, GBPS and breath-hold cine MRI performed according to standard protocols. RESULTS: Normal ranges for RV ejection fraction (RVEF) defined as mean +/- 2SD were 0.49-0.72, 0.44-0.66 and 0.40-0.69 when measured by MRI, FP and GBPS respectively. Bland-Altman analysis showed a mean difference (bias) between MRI and FP of 0.05 (95% CI: 0.03-0.08) and of 0.06 (95% CI: 0.02-0.10) between MRI and GBPS. No systematic bias was found between FP and GBPS. Normal values for RV end-diastolic volume index (RVEDVI) were 37-95 and 29-91 ml m(-2) when measured by MRI and GBPS respectively. The mean difference between RVEDVI was 6 ml m(-2) (95% CI: 0-11). CONCLUSIONS: (i) Normal values of RVEF differ between MRI, FP and GBPS with wide limits of agreement, accordingly it is difficult to evaluate changes over time if measured by different methods, (ii) RV volumes are in the same range when measured by MRI or GBPS but with wide limits of agreement, and (iii) if MRI is considered gold standard then FP is more accurate than GBPS for RVEF measurements.

U2 - 10.1111/j.1475-097X.2005.00635.x

DO - 10.1111/j.1475-097X.2005.00635.x

M3 - Journal article

C2 - 16268986

VL - 25

SP - 344

EP - 349

JO - Clinical Physiology and Functional Imaging

JF - Clinical Physiology and Functional Imaging

SN - 1475-0961

IS - 6

ER -

ID: 8464901