Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions. / Sathananthan, Janarthanan; Fraser, Rob; Kütting, Maximilian; Hensey, Mark; Landes, Uri; Alkhodair, Abdullah; Sedaghat, Alexander; Blanke, Philipp; Toggweiler, Stefan; Leipsic, Jonathon; Søndergaard, Lars; Wood, David; Webb, John G.

I: EuroIntervention, Bind 15, Nr. 15, 2020, s. E1335-E1342.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Sathananthan, J, Fraser, R, Kütting, M, Hensey, M, Landes, U, Alkhodair, A, Sedaghat, A, Blanke, P, Toggweiler, S, Leipsic, J, Søndergaard, L, Wood, D & Webb, JG 2020, 'Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions', EuroIntervention, bind 15, nr. 15, s. E1335-E1342. https://doi.org/10.4244/EIJ-D-19-00782

APA

Sathananthan, J., Fraser, R., Kütting, M., Hensey, M., Landes, U., Alkhodair, A., Sedaghat, A., Blanke, P., Toggweiler, S., Leipsic, J., Søndergaard, L., Wood, D., & Webb, J. G. (2020). Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions. EuroIntervention, 15(15), E1335-E1342. https://doi.org/10.4244/EIJ-D-19-00782

Vancouver

Sathananthan J, Fraser R, Kütting M, Hensey M, Landes U, Alkhodair A o.a. Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions. EuroIntervention. 2020;15(15):E1335-E1342. https://doi.org/10.4244/EIJ-D-19-00782

Author

Sathananthan, Janarthanan ; Fraser, Rob ; Kütting, Maximilian ; Hensey, Mark ; Landes, Uri ; Alkhodair, Abdullah ; Sedaghat, Alexander ; Blanke, Philipp ; Toggweiler, Stefan ; Leipsic, Jonathon ; Søndergaard, Lars ; Wood, David ; Webb, John G. / Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions. I: EuroIntervention. 2020 ; Bind 15, Nr. 15. s. E1335-E1342.

Bibtex

@article{d0cd1fbcba204fca8e45449c15943681,
title = "Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions",
abstract = "Aims: We aimed to assess the impact of implant depth on hydrodynamic function following valve-in-valve (VIV) intervention using the ALLEGRA transcatheter heart valve (THV) in three different surgical valve designs. Methods and results: Multiple implantation depths (+2 mm, -2 mm and -6 mm) were tested using a 23 mm ALLEGRA THV for VIV intervention in 19 mm, 21 mm, 23 mm, and 25 mm Epic, Mitroflow and Magna Ease bioprosthetic valves. Multimodality imaging and hydrodynamic evaluation was performed at each implantation depth. The 23 mm ALLEGRA valve had gradients <20 mmHg in the Mitroflow and Epic valves sized ≥21 mm, and in all sizes of the Magna Ease valve. Gradients did not increase significantly at lower implantation depths. The 19 mm Epic (+2 mm: 20.1±0.6 mmHg, -2 mm: 18.8±0.5 mmHg, -6 mm: 22.8±0.3 mmHg) and 19 mm Mitroflow (+2 mm: 24.1±0.2 mmHg, -2 mm: 31.5±0.3 mmHg, -6 mm: 25.6±0.2 mmHg) valves had elevated mean gradients. In larger sized surgical valves (≥23 mm) the regurgitant fraction was higher at low implantation depths. Pinwheeling was significantly worse in the smaller sized (≤21 mm) surgical valves and also at low (<-2 mm) implantation depth. Conclusions: The 23 mm ALLEGRA valve had favourable (<20 mmHg) gradients in all surgical valves sized ≥21 mm, even when the THV was implanted low. In 19 mm sized Mitroflow and Epic valves, gradients were elevated (>20 mmHg). While there was no major difference in mean transvalvular gradients, leaflet pinwheeling was worse at lower implantation depths.",
keywords = "Aortic stenosis, Degenerative valve, Prior cardiovascular surgery, TAVI, Valve restenosis, Valve-in-valve",
author = "Janarthanan Sathananthan and Rob Fraser and Maximilian K{\"u}tting and Mark Hensey and Uri Landes and Abdullah Alkhodair and Alexander Sedaghat and Philipp Blanke and Stefan Toggweiler and Jonathon Leipsic and Lars S{\o}ndergaard and David Wood and Webb, {John G.}",
year = "2020",
doi = "10.4244/EIJ-D-19-00782",
language = "English",
volume = "15",
pages = "E1335--E1342",
journal = "EuroIntervention",
issn = "1774-024X",
publisher = "Europa Digital & Publishing",
number = "15",

}

RIS

TY - JOUR

T1 - Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions

AU - Sathananthan, Janarthanan

AU - Fraser, Rob

AU - Kütting, Maximilian

AU - Hensey, Mark

AU - Landes, Uri

AU - Alkhodair, Abdullah

AU - Sedaghat, Alexander

AU - Blanke, Philipp

AU - Toggweiler, Stefan

AU - Leipsic, Jonathon

AU - Søndergaard, Lars

AU - Wood, David

AU - Webb, John G.

PY - 2020

Y1 - 2020

N2 - Aims: We aimed to assess the impact of implant depth on hydrodynamic function following valve-in-valve (VIV) intervention using the ALLEGRA transcatheter heart valve (THV) in three different surgical valve designs. Methods and results: Multiple implantation depths (+2 mm, -2 mm and -6 mm) were tested using a 23 mm ALLEGRA THV for VIV intervention in 19 mm, 21 mm, 23 mm, and 25 mm Epic, Mitroflow and Magna Ease bioprosthetic valves. Multimodality imaging and hydrodynamic evaluation was performed at each implantation depth. The 23 mm ALLEGRA valve had gradients <20 mmHg in the Mitroflow and Epic valves sized ≥21 mm, and in all sizes of the Magna Ease valve. Gradients did not increase significantly at lower implantation depths. The 19 mm Epic (+2 mm: 20.1±0.6 mmHg, -2 mm: 18.8±0.5 mmHg, -6 mm: 22.8±0.3 mmHg) and 19 mm Mitroflow (+2 mm: 24.1±0.2 mmHg, -2 mm: 31.5±0.3 mmHg, -6 mm: 25.6±0.2 mmHg) valves had elevated mean gradients. In larger sized surgical valves (≥23 mm) the regurgitant fraction was higher at low implantation depths. Pinwheeling was significantly worse in the smaller sized (≤21 mm) surgical valves and also at low (<-2 mm) implantation depth. Conclusions: The 23 mm ALLEGRA valve had favourable (<20 mmHg) gradients in all surgical valves sized ≥21 mm, even when the THV was implanted low. In 19 mm sized Mitroflow and Epic valves, gradients were elevated (>20 mmHg). While there was no major difference in mean transvalvular gradients, leaflet pinwheeling was worse at lower implantation depths.

AB - Aims: We aimed to assess the impact of implant depth on hydrodynamic function following valve-in-valve (VIV) intervention using the ALLEGRA transcatheter heart valve (THV) in three different surgical valve designs. Methods and results: Multiple implantation depths (+2 mm, -2 mm and -6 mm) were tested using a 23 mm ALLEGRA THV for VIV intervention in 19 mm, 21 mm, 23 mm, and 25 mm Epic, Mitroflow and Magna Ease bioprosthetic valves. Multimodality imaging and hydrodynamic evaluation was performed at each implantation depth. The 23 mm ALLEGRA valve had gradients <20 mmHg in the Mitroflow and Epic valves sized ≥21 mm, and in all sizes of the Magna Ease valve. Gradients did not increase significantly at lower implantation depths. The 19 mm Epic (+2 mm: 20.1±0.6 mmHg, -2 mm: 18.8±0.5 mmHg, -6 mm: 22.8±0.3 mmHg) and 19 mm Mitroflow (+2 mm: 24.1±0.2 mmHg, -2 mm: 31.5±0.3 mmHg, -6 mm: 25.6±0.2 mmHg) valves had elevated mean gradients. In larger sized surgical valves (≥23 mm) the regurgitant fraction was higher at low implantation depths. Pinwheeling was significantly worse in the smaller sized (≤21 mm) surgical valves and also at low (<-2 mm) implantation depth. Conclusions: The 23 mm ALLEGRA valve had favourable (<20 mmHg) gradients in all surgical valves sized ≥21 mm, even when the THV was implanted low. In 19 mm sized Mitroflow and Epic valves, gradients were elevated (>20 mmHg). While there was no major difference in mean transvalvular gradients, leaflet pinwheeling was worse at lower implantation depths.

KW - Aortic stenosis

KW - Degenerative valve

KW - Prior cardiovascular surgery

KW - TAVI

KW - Valve restenosis

KW - Valve-in-valve

U2 - 10.4244/EIJ-D-19-00782

DO - 10.4244/EIJ-D-19-00782

M3 - Journal article

C2 - 31607682

AN - SCOPUS:85083368172

VL - 15

SP - E1335-E1342

JO - EuroIntervention

JF - EuroIntervention

SN - 1774-024X

IS - 15

ER -

ID: 250168558