Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41 patients. With the same SPECT the distribution of PAO was measured after intravenous injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6-10 mm (HR) and 15-20 mm (LR). PAO images showed close resemblance to 133Xe CBF tomograms. Only 20 per cent of the (decay corrected) brain counts were lost during 24 hours.

OriginalsprogEngelsk
BogserieActa Radiologica. Supplementum
Vol/bind369
Sider (fra-til)456-9
Antal sider4
ISSN0365-5954
StatusUdgivet - 1986

ID: 275604118