Comparative study of HbA1c and fasting plasma glucose vs the oral glucose tolerance test for diagnosis of diabetes in people with tuberculosis
Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Standard
Comparative study of HbA1c and fasting plasma glucose vs the oral glucose tolerance test for diagnosis of diabetes in people with tuberculosis. / Aftab, H.; Ambreen, A.; Jamil, M.; Garred, P.; Petersen, J. H.; Nielsen, S. D.; Bygbjerg, I. C.; Christensen, D. L.
I: Diabetic Medicine, Bind 34, Nr. 6, 06.2017, s. 800-803.Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Comparative study of HbA1c and fasting plasma glucose vs the oral glucose tolerance test for diagnosis of diabetes in people with tuberculosis
AU - Aftab, H.
AU - Ambreen, A.
AU - Jamil, M.
AU - Garred, P.
AU - Petersen, J. H.
AU - Nielsen, S. D.
AU - Bygbjerg, I. C.
AU - Christensen, D. L.
PY - 2017/6
Y1 - 2017/6
N2 - Aim: To compare HbA1c and fasting plasma glucose assessment, with the 2-h oral glucose tolerance test as reference, in screening for diabetes in people with turberculosis. Methods: Individuals (N=268) with newly diagnosed smear-positive tuberculosis were screened for diabetes at a tertiary hospital in Lahore, Pakistan. Diabetes diagnosis was based on WHO criteria: thresholds were ≥48 mmol/mol (≥6.5%) for HbA1c and ≥7.0mmol/l for fasting plasma glucose. Results: The proportion of participants diagnosed with diabetes was 4.9% (n =13) by oral glucose tolerance test, while 11.9% (n =32) and 14.6% (n =39) were diagnosed with diabetes using HbA1c and fasting plasma glucose criteria, respectively. The area under the receiver-operating characteristic curve was 0.79 (95% CI 0.64 to 0.94) for HbA1c and 0.61 (95% CI 0.50 to 0.73) for fasting plasma glucose, with a borderline significant difference between the two tests (P=0.07). Conclusions: HbA1c and fasting plasma glucose performed equally in terms of diagnosing new diabetes cases in individuals with tuberculosis, but the proportion of participants falsely classified as positive was higher for fasting plasma glucose. This may be explained by acute blood glucose fluctuations when using fasting plasma glucose. HbA1c may be a more reliable test in individuals with transient hyperglycaemia.
AB - Aim: To compare HbA1c and fasting plasma glucose assessment, with the 2-h oral glucose tolerance test as reference, in screening for diabetes in people with turberculosis. Methods: Individuals (N=268) with newly diagnosed smear-positive tuberculosis were screened for diabetes at a tertiary hospital in Lahore, Pakistan. Diabetes diagnosis was based on WHO criteria: thresholds were ≥48 mmol/mol (≥6.5%) for HbA1c and ≥7.0mmol/l for fasting plasma glucose. Results: The proportion of participants diagnosed with diabetes was 4.9% (n =13) by oral glucose tolerance test, while 11.9% (n =32) and 14.6% (n =39) were diagnosed with diabetes using HbA1c and fasting plasma glucose criteria, respectively. The area under the receiver-operating characteristic curve was 0.79 (95% CI 0.64 to 0.94) for HbA1c and 0.61 (95% CI 0.50 to 0.73) for fasting plasma glucose, with a borderline significant difference between the two tests (P=0.07). Conclusions: HbA1c and fasting plasma glucose performed equally in terms of diagnosing new diabetes cases in individuals with tuberculosis, but the proportion of participants falsely classified as positive was higher for fasting plasma glucose. This may be explained by acute blood glucose fluctuations when using fasting plasma glucose. HbA1c may be a more reliable test in individuals with transient hyperglycaemia.
U2 - 10.1111/dme.13354
DO - 10.1111/dme.13354
M3 - Journal article
C2 - 28326618
AN - SCOPUS:85017452400
VL - 34
SP - 800
EP - 803
JO - Diabetic Medicine
JF - Diabetic Medicine
SN - 0742-3071
IS - 6
ER -
ID: 188757273