Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch. / Millan-Iturbe, Oscar; Sawaya, Fadi J.; Bieliauskas, Gintautas; Chow, Danny H.F.; De Backer, Ole; Søndergaard, Lars.

I: Canadian Journal of Cardiology, Bind 33, Nr. 9, 09.2017, s. 1206.e1-1206.e3.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Millan-Iturbe, O, Sawaya, FJ, Bieliauskas, G, Chow, DHF, De Backer, O & Søndergaard, L 2017, 'Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch', Canadian Journal of Cardiology, bind 33, nr. 9, s. 1206.e1-1206.e3. https://doi.org/10.1016/j.cjca.2017.03.018

APA

Millan-Iturbe, O., Sawaya, F. J., Bieliauskas, G., Chow, D. H. F., De Backer, O., & Søndergaard, L. (2017). Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch. Canadian Journal of Cardiology, 33(9), 1206.e1-1206.e3. https://doi.org/10.1016/j.cjca.2017.03.018

Vancouver

Millan-Iturbe O, Sawaya FJ, Bieliauskas G, Chow DHF, De Backer O, Søndergaard L. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch. Canadian Journal of Cardiology. 2017 sep.;33(9):1206.e1-1206.e3. https://doi.org/10.1016/j.cjca.2017.03.018

Author

Millan-Iturbe, Oscar ; Sawaya, Fadi J. ; Bieliauskas, Gintautas ; Chow, Danny H.F. ; De Backer, Ole ; Søndergaard, Lars. / Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch. I: Canadian Journal of Cardiology. 2017 ; Bind 33, Nr. 9. s. 1206.e1-1206.e3.

Bibtex

@article{c4931a60ccba4cf1b76f0cfa0e007dfc,
title = "Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch",
abstract = "Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a “gothic aortic arch”; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair.",
author = "Oscar Millan-Iturbe and Sawaya, {Fadi J.} and Gintautas Bieliauskas and Chow, {Danny H.F.} and {De Backer}, Ole and Lars S{\o}ndergaard",
year = "2017",
month = sep,
doi = "10.1016/j.cjca.2017.03.018",
language = "English",
volume = "33",
pages = "1206.e1--1206.e3",
journal = "Canadian Journal of Cardiology",
issn = "0828-282X",
publisher = "Elsevier",
number = "9",

}

RIS

TY - JOUR

T1 - Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch

AU - Millan-Iturbe, Oscar

AU - Sawaya, Fadi J.

AU - Bieliauskas, Gintautas

AU - Chow, Danny H.F.

AU - De Backer, Ole

AU - Søndergaard, Lars

PY - 2017/9

Y1 - 2017/9

N2 - Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a “gothic aortic arch”; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair.

AB - Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a “gothic aortic arch”; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair.

U2 - 10.1016/j.cjca.2017.03.018

DO - 10.1016/j.cjca.2017.03.018

M3 - Journal article

C2 - 28583399

AN - SCOPUS:85020101961

VL - 33

SP - 1206.e1-1206.e3

JO - Canadian Journal of Cardiology

JF - Canadian Journal of Cardiology

SN - 0828-282X

IS - 9

ER -

ID: 189736411