Transcatheter aortic valve implantation with the ACURATE neo valve: indications, procedural aspects and clinical outcomes
Publikation: Bidrag til tidsskrift › Review › Forskning › fagfællebedømt
Standard
Transcatheter aortic valve implantation with the ACURATE neo valve : indications, procedural aspects and clinical outcomes. / Collaborators.
I: EuroIntervention, Bind 15, Nr. 18, 2020, s. e1571-e1579.Publikation: Bidrag til tidsskrift › Review › Forskning › fagfællebedømt
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Transcatheter aortic valve implantation with the ACURATE neo valve
T2 - indications, procedural aspects and clinical outcomes
AU - Kim, Won-Keun
AU - Hengstenberg, Christian
AU - Hilker, Michael
AU - Schäfer, Ulrich
AU - Rudolph, Tanja K
AU - Toggweiler, Stefan
AU - Rück, Andreas
AU - Søndergaard, Lars
AU - Conradi, Lenard
AU - Hamm, Christian
AU - Walther, Thomas
AU - Möllmann, Helge
AU - Collaborators
PY - 2020
Y1 - 2020
N2 - The ACURATE neo aortic valve system is a self-expanding transcatheter device that was granted CE mark in 2014 and has since been widely adopted in the treatment of patients with severe aortic stenosis. The ACURATE neo can be used in a wide clinical spectrum, but there are some specific indications and anatomies where this device is particularly suitable. Recently, it was shown that, with appropriate patient screening, size selection, and optimised positioning, results can be improved substantially. This review provides an overview of existing data and compiles a standardised manual of best practice for the implantation of this device based on both evidence and individual experience.
AB - The ACURATE neo aortic valve system is a self-expanding transcatheter device that was granted CE mark in 2014 and has since been widely adopted in the treatment of patients with severe aortic stenosis. The ACURATE neo can be used in a wide clinical spectrum, but there are some specific indications and anatomies where this device is particularly suitable. Recently, it was shown that, with appropriate patient screening, size selection, and optimised positioning, results can be improved substantially. This review provides an overview of existing data and compiles a standardised manual of best practice for the implantation of this device based on both evidence and individual experience.
KW - Aortic Valve/diagnostic imaging
KW - Aortic Valve Stenosis/diagnostic imaging
KW - Heart Valve Prosthesis
KW - Humans
KW - Prosthesis Design
KW - Transcatheter Aortic Valve Replacement/adverse effects
KW - Treatment Outcome
U2 - 10.4244/EIJ-D-19-00908
DO - 10.4244/EIJ-D-19-00908
M3 - Review
C2 - 31911402
VL - 15
SP - e1571-e1579
JO - EuroIntervention
JF - EuroIntervention
SN - 1774-024X
IS - 18
ER -
ID: 269534609