Laser-induced thermal coagulation enhances skin uptake of topically applied compounds

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Laser-induced thermal coagulation enhances skin uptake of topically applied compounds. / Haak, C S; Hannibal, J; Paasch, U; Anderson, R R; Haedersdal, M.

I: Lasers in Surgery and Medicine, Bind 49, Nr. 6, 2017, s. 582-591.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Haak, CS, Hannibal, J, Paasch, U, Anderson, RR & Haedersdal, M 2017, 'Laser-induced thermal coagulation enhances skin uptake of topically applied compounds', Lasers in Surgery and Medicine, bind 49, nr. 6, s. 582-591. https://doi.org/10.1002/lsm.22642

APA

Haak, C. S., Hannibal, J., Paasch, U., Anderson, R. R., & Haedersdal, M. (2017). Laser-induced thermal coagulation enhances skin uptake of topically applied compounds. Lasers in Surgery and Medicine, 49(6), 582-591. https://doi.org/10.1002/lsm.22642

Vancouver

Haak CS, Hannibal J, Paasch U, Anderson RR, Haedersdal M. Laser-induced thermal coagulation enhances skin uptake of topically applied compounds. Lasers in Surgery and Medicine. 2017;49(6):582-591. https://doi.org/10.1002/lsm.22642

Author

Haak, C S ; Hannibal, J ; Paasch, U ; Anderson, R R ; Haedersdal, M. / Laser-induced thermal coagulation enhances skin uptake of topically applied compounds. I: Lasers in Surgery and Medicine. 2017 ; Bind 49, Nr. 6. s. 582-591.

Bibtex

@article{885f957b99b1452a820f6dc7992a28dc,
title = "Laser-induced thermal coagulation enhances skin uptake of topically applied compounds",
abstract = "BACKGROUND: Ablative fractional laser (AFL) generates microchannels in skin surrounded by a zone of thermally altered tissue, termed the coagulation zone (CZ). The thickness of CZ varies according to applied wavelength and laser settings. It is well-known that AFL channels facilitate uptake of topically applied compounds, but the importance of CZ is unknown.METHODS: Franz Cells were used to investigate skin uptake and permeation of fluorescent labeled polyethylene glycols (PEGs) with mean molecular weights (MW) of 350, 1,000, and 5,000 Da. Microchannels with CZ thicknesses ranging from 0 to 80 μm were generated from micro-needles (0 μm, CZ-0), and AFL (10,600 nm) applied to -80°C deep frozen skin (20 μm, CZ-20) and skin equilibrated to room temperature (80 μm, CZ-80). Channels penetrated into similar mid-dermal skin depths of 600-700 μm, and number of channels per skin area was similar. At 4 hours incubation, skin uptake of PEGs into CZ and dermis was evaluated by fluorescence microscopy at specific skin depths of 150, 400, and 1,000 μm and the transcutaneous permeation was quantified by fluorescence of receptor fluids.RESULTS: Overall, the highest uptake of PEGs was reached through microchannels surrounded by CZ compared to channels with no CZ (CZ-20 and CZ-80>CZ-0).The thickness of CZ affected PEG distribution in skin. A thin CZ-20 favored significantly higher mean fluorescence intensities inside CZ areas compared to CZ-80 (PEG 350, 1,000, and 5,000; P < 0.001). In dermis, the uptake through CZ-20 channels was significantly higher than through CZ-80 and CZ-0 at all skin depths (PEG 350, 1,000 and 5,000, 150-1,000 μm; P < 0.001). Correspondingly, transcutaneous permeation of PEG 350 was highest in CZ-20 compared to CZ-80 and CZ-0 samples (P < 0.001). Permeation of larger molecules (PEG 1,000 and PEG 5,000) was generally low.CONCLUSION: Uptake of topical compounds is higher through microchannels surrounded by a CZ than without a CZ. Moreover, CZ thickness influences PEG distribution, with highest PEG uptake achieved from microchannels surrounded by a thin CZ. Lasers Surg. Med. 49:582-591, 2017. {\textcopyright} 2017 Wiley Periodicals, Inc.",
author = "Haak, {C S} and J Hannibal and U Paasch and Anderson, {R R} and M Haedersdal",
note = "{\textcopyright} 2017 Wiley Periodicals, Inc.",
year = "2017",
doi = "10.1002/lsm.22642",
language = "English",
volume = "49",
pages = "582--591",
journal = "Lasers in Surgery and Medicine",
issn = "0196-8092",
publisher = "JohnWiley & Sons, Inc.",
number = "6",

}

RIS

TY - JOUR

T1 - Laser-induced thermal coagulation enhances skin uptake of topically applied compounds

AU - Haak, C S

AU - Hannibal, J

AU - Paasch, U

AU - Anderson, R R

AU - Haedersdal, M

N1 - © 2017 Wiley Periodicals, Inc.

PY - 2017

Y1 - 2017

N2 - BACKGROUND: Ablative fractional laser (AFL) generates microchannels in skin surrounded by a zone of thermally altered tissue, termed the coagulation zone (CZ). The thickness of CZ varies according to applied wavelength and laser settings. It is well-known that AFL channels facilitate uptake of topically applied compounds, but the importance of CZ is unknown.METHODS: Franz Cells were used to investigate skin uptake and permeation of fluorescent labeled polyethylene glycols (PEGs) with mean molecular weights (MW) of 350, 1,000, and 5,000 Da. Microchannels with CZ thicknesses ranging from 0 to 80 μm were generated from micro-needles (0 μm, CZ-0), and AFL (10,600 nm) applied to -80°C deep frozen skin (20 μm, CZ-20) and skin equilibrated to room temperature (80 μm, CZ-80). Channels penetrated into similar mid-dermal skin depths of 600-700 μm, and number of channels per skin area was similar. At 4 hours incubation, skin uptake of PEGs into CZ and dermis was evaluated by fluorescence microscopy at specific skin depths of 150, 400, and 1,000 μm and the transcutaneous permeation was quantified by fluorescence of receptor fluids.RESULTS: Overall, the highest uptake of PEGs was reached through microchannels surrounded by CZ compared to channels with no CZ (CZ-20 and CZ-80>CZ-0).The thickness of CZ affected PEG distribution in skin. A thin CZ-20 favored significantly higher mean fluorescence intensities inside CZ areas compared to CZ-80 (PEG 350, 1,000, and 5,000; P < 0.001). In dermis, the uptake through CZ-20 channels was significantly higher than through CZ-80 and CZ-0 at all skin depths (PEG 350, 1,000 and 5,000, 150-1,000 μm; P < 0.001). Correspondingly, transcutaneous permeation of PEG 350 was highest in CZ-20 compared to CZ-80 and CZ-0 samples (P < 0.001). Permeation of larger molecules (PEG 1,000 and PEG 5,000) was generally low.CONCLUSION: Uptake of topical compounds is higher through microchannels surrounded by a CZ than without a CZ. Moreover, CZ thickness influences PEG distribution, with highest PEG uptake achieved from microchannels surrounded by a thin CZ. Lasers Surg. Med. 49:582-591, 2017. © 2017 Wiley Periodicals, Inc.

AB - BACKGROUND: Ablative fractional laser (AFL) generates microchannels in skin surrounded by a zone of thermally altered tissue, termed the coagulation zone (CZ). The thickness of CZ varies according to applied wavelength and laser settings. It is well-known that AFL channels facilitate uptake of topically applied compounds, but the importance of CZ is unknown.METHODS: Franz Cells were used to investigate skin uptake and permeation of fluorescent labeled polyethylene glycols (PEGs) with mean molecular weights (MW) of 350, 1,000, and 5,000 Da. Microchannels with CZ thicknesses ranging from 0 to 80 μm were generated from micro-needles (0 μm, CZ-0), and AFL (10,600 nm) applied to -80°C deep frozen skin (20 μm, CZ-20) and skin equilibrated to room temperature (80 μm, CZ-80). Channels penetrated into similar mid-dermal skin depths of 600-700 μm, and number of channels per skin area was similar. At 4 hours incubation, skin uptake of PEGs into CZ and dermis was evaluated by fluorescence microscopy at specific skin depths of 150, 400, and 1,000 μm and the transcutaneous permeation was quantified by fluorescence of receptor fluids.RESULTS: Overall, the highest uptake of PEGs was reached through microchannels surrounded by CZ compared to channels with no CZ (CZ-20 and CZ-80>CZ-0).The thickness of CZ affected PEG distribution in skin. A thin CZ-20 favored significantly higher mean fluorescence intensities inside CZ areas compared to CZ-80 (PEG 350, 1,000, and 5,000; P < 0.001). In dermis, the uptake through CZ-20 channels was significantly higher than through CZ-80 and CZ-0 at all skin depths (PEG 350, 1,000 and 5,000, 150-1,000 μm; P < 0.001). Correspondingly, transcutaneous permeation of PEG 350 was highest in CZ-20 compared to CZ-80 and CZ-0 samples (P < 0.001). Permeation of larger molecules (PEG 1,000 and PEG 5,000) was generally low.CONCLUSION: Uptake of topical compounds is higher through microchannels surrounded by a CZ than without a CZ. Moreover, CZ thickness influences PEG distribution, with highest PEG uptake achieved from microchannels surrounded by a thin CZ. Lasers Surg. Med. 49:582-591, 2017. © 2017 Wiley Periodicals, Inc.

U2 - 10.1002/lsm.22642

DO - 10.1002/lsm.22642

M3 - Journal article

C2 - 28181673

VL - 49

SP - 582

EP - 591

JO - Lasers in Surgery and Medicine

JF - Lasers in Surgery and Medicine

SN - 0196-8092

IS - 6

ER -

ID: 193506727