Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss: case report

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss : case report. / Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov; Kofoed, Klaus Fuglsang; Kastrup, Jens.

I: Magnetic Resonance Imaging, Bind 30, Nr. 6, 2012, s. 889-92.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Qayyum, AA, Vejlstrup, NG, Ahtarovski, KA, Kofoed, KF & Kastrup, J 2012, 'Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss: case report', Magnetic Resonance Imaging, bind 30, nr. 6, s. 889-92. https://doi.org/10.1016/j.mri.2012.02.023

APA

Qayyum, A. A., Vejlstrup, N. G., Ahtarovski, K. A., Kofoed, K. F., & Kastrup, J. (2012). Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss: case report. Magnetic Resonance Imaging, 30(6), 889-92. https://doi.org/10.1016/j.mri.2012.02.023

Vancouver

Qayyum AA, Vejlstrup NG, Ahtarovski KA, Kofoed KF, Kastrup J. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss: case report. Magnetic Resonance Imaging. 2012;30(6):889-92. https://doi.org/10.1016/j.mri.2012.02.023

Author

Qayyum, Abbas Ali ; Vejlstrup, Niels Grove ; Ahtarovski, Kiril Aleksov ; Kofoed, Klaus Fuglsang ; Kastrup, Jens. / Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss : case report. I: Magnetic Resonance Imaging. 2012 ; Bind 30, Nr. 6. s. 889-92.

Bibtex

@article{e25c5d73f9f2456cbb16e69cc57d4ef5,
title = "Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss: case report",
abstract = "Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor.",
author = "Qayyum, {Abbas Ali} and Vejlstrup, {Niels Grove} and Ahtarovski, {Kiril Aleksov} and Kofoed, {Klaus Fuglsang} and Jens Kastrup",
note = "Crown Copyright {\textcopyright} 2012. Published by Elsevier Inc. All rights reserved.",
year = "2012",
doi = "10.1016/j.mri.2012.02.023",
language = "English",
volume = "30",
pages = "889--92",
journal = "Magnetic Resonance Imaging",
issn = "0730-725X",
publisher = "Elsevier",
number = "6",

}

RIS

TY - JOUR

T1 - Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss

T2 - case report

AU - Qayyum, Abbas Ali

AU - Vejlstrup, Niels Grove

AU - Ahtarovski, Kiril Aleksov

AU - Kofoed, Klaus Fuglsang

AU - Kastrup, Jens

N1 - Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

PY - 2012

Y1 - 2012

N2 - Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor.

AB - Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor.

U2 - 10.1016/j.mri.2012.02.023

DO - 10.1016/j.mri.2012.02.023

M3 - Journal article

C2 - 22495236

VL - 30

SP - 889

EP - 892

JO - Magnetic Resonance Imaging

JF - Magnetic Resonance Imaging

SN - 0730-725X

IS - 6

ER -

ID: 48493535