Fluorescence molecular tomography (FMT) is a promising tool for real time in vivo quantification of neurotransmission (NT) as we pursue in our BRAIN initiative effort. However, the acquired image data are noisy and the reconstruction problem is ill-posed. Further, while spatial sparsity of the NT effects could be exploited, traditional compressive-sensing methods cannot be directly applied as the system matrix in FMT is highly coherent. To overcome these issues, we propose and assess a three-step reconstruction method. First, truncated singular value decomposition is applied on the data to reduce matrix coherence. The resultant image data are input to a homotopy-based reconstruction strategy that exploits sparsity via ℓ1 regularization. The reconstructed image is then input to a maximum-likelihood expectation maximization (MLEM) algorithm that retains the sparseness of the input estimate and improves upon the quantitation by accurate Poisson noise modeling. The proposed reconstruction method was evaluated in a three-dimensional simulated setup with fluorescent sources in a cuboidal scattering medium with optical properties simulating human brain cortex (reduced scattering coefficient: 9.2 cm-1, absorption coefficient: 0.1 cm-1 and tomographic measurements made using pixelated detectors. In different experiments, fluorescent sources of varying size and intensity were simulated. The proposed reconstruction method provided accurate estimates of the fluorescent source intensity, with a 20% lower root mean square error on average compared to the pure-homotopy method for all considered source intensities and sizes. Further, compared with conventional ℓ2 regularized algorithm, overall, the proposed method reconstructed substantially more accurate fluorescence distribution. The proposed method shows considerable promise and will be tested using more realistic simulations and experimental setups.

OriginalsprogEngelsk
TitelOptical Tomography and Spectroscopy of Tissue XII
Antal sider8
Vol/bind10059
ForlagSPIE - International Society for Optical Engineering
Publikationsdato2017
Artikelnummer1005911
ISBN (Elektronisk)9781510605596
DOI
StatusUdgivet - 2017
BegivenhedOptical Tomography and Spectroscopy of Tissue XII - San Francisco, USA
Varighed: 30 jan. 20171 feb. 2017

Konference

KonferenceOptical Tomography and Spectroscopy of Tissue XII
LandUSA
BySan Francisco
Periode30/01/201701/02/2017
SponsorThe Society of Photo-Optical Instrumentation Engineers (SPIE)

ID: 188452314