Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room. / Saha, Chayan Kumer; Zhang, Guoqiang; Kai, Peter; Bjerg, Bjarne Schmidt.

In: Biosystems Engineering, Vol. 105, No. 3, 2010, p. 279-287.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Saha, CK, Zhang, G, Kai, P & Bjerg, BS 2010, 'Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room', Biosystems Engineering, vol. 105, no. 3, pp. 279-287. https://doi.org/10.1016/j.biosystemseng.2009.11.006

APA

Saha, C. K., Zhang, G., Kai, P., & Bjerg, B. S. (2010). Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room. Biosystems Engineering, 105(3), 279-287. https://doi.org/10.1016/j.biosystemseng.2009.11.006

Vancouver

Saha CK, Zhang G, Kai P, Bjerg BS. Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room. Biosystems Engineering. 2010;105(3):279-287. https://doi.org/10.1016/j.biosystemseng.2009.11.006

Author

Saha, Chayan Kumer ; Zhang, Guoqiang ; Kai, Peter ; Bjerg, Bjarne Schmidt. / Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room. In: Biosystems Engineering. 2010 ; Vol. 105, No. 3. pp. 279-287.

Bibtex

@article{d4f1a3107f9311df928f000ea68e967b,
title = "Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room",
author = "Saha, {Chayan Kumer} and Guoqiang Zhang and Peter Kai and Bjerg, {Bjarne Schmidt}",
year = "2010",
doi = "10.1016/j.biosystemseng.2009.11.006",
language = "English",
volume = "105",
pages = "279--287",
journal = "Biosystems Engineering",
issn = "1537-5110",
publisher = "Academic Press",
number = "3",

}

RIS

TY - JOUR

T1 - Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room

AU - Saha, Chayan Kumer

AU - Zhang, Guoqiang

AU - Kai, Peter

AU - Bjerg, Bjarne Schmidt

PY - 2010

Y1 - 2010

U2 - 10.1016/j.biosystemseng.2009.11.006

DO - 10.1016/j.biosystemseng.2009.11.006

M3 - Journal article

VL - 105

SP - 279

EP - 287

JO - Biosystems Engineering

JF - Biosystems Engineering

SN - 1537-5110

IS - 3

ER -

ID: 20473396