Pharmacokinetic Analysis of 64Cu-ATSM Dynamic PET in Human Xenograft Tumors in Mice

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

The aim of this study was to evaluate the feasibility to perform voxel-wise kinetic modeling on datasets obtained from tumor-bearing mice that underwent dynamic PET scans with 64Cu-ATSM and extract useful physiological parameters.METHODS: Tumor-bearing mice underwent 90-min dynamic PET scans with 64Cu-ATSM and CT scans with contrast. Irreversible and reversible two-tissue compartment models were fitted to time activity curves (TACs) obtained from whole tumor volumes and compared using the Akaike information criterion (AIC). Based on voxel-wise pharmacokinetic analysis, parametric maps of model rate constants k₁, k₃ and Ki were generated and compared to 64Cu-ATSM uptake.RESULTS: Based on the AIC, an irreversible two-tissue compartment model was selected for voxel-wise pharmacokinetic analysis. Of the extracted parameters, k₁ (~perfusion) showed a strong correlation with early tracer uptake (mean spearman R = 0.88) 5 min post injection (pi). Moreover, positive relationships were found between late tracer uptake (90 min pi) and both k₃ and the net influx rate constant, Ki (mean spearman R = 0.56 and R = 0.86; respectively).CONCLUSION: This study shows the feasibility to extract relevant parameters from voxel-wise pharmacokinetic analysis to be used for preclinical validation of 64Cu-ATSM as a hypoxia-specific PET tracer.
OriginalsprogEngelsk
TidsskriftDiagnostics
Vol/bind5
Udgave nummer2
Sider (fra-til)96-112
Antal sider17
ISSN2075-4418
DOI
StatusUdgivet - 27 mar. 2015

ID: 160309787