Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Spontaneous baroreflex sensitivity : prospective validation trial of a novel technique in survivors of acute myocardial infarction. / Barthel, Petra; Bauer, Axel; Müller, Alexander; Huster, Katharina M; Kanters, Jørgen K.; Paruchuri, Vijayapraveena; Yang, Xiaoyun; Ulm, Kurt; Malik, Marek; Schmidt, Georg.

I: Heart rhythm : the official journal of the Heart Rhythm Society, Bind 9, Nr. 8, 08.2012, s. 1288-94.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Barthel, P, Bauer, A, Müller, A, Huster, KM, Kanters, JK, Paruchuri, V, Yang, X, Ulm, K, Malik, M & Schmidt, G 2012, 'Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction', Heart rhythm : the official journal of the Heart Rhythm Society, bind 9, nr. 8, s. 1288-94. https://doi.org/10.1016/j.hrthm.2012.04.017

APA

Barthel, P., Bauer, A., Müller, A., Huster, K. M., Kanters, J. K., Paruchuri, V., Yang, X., Ulm, K., Malik, M., & Schmidt, G. (2012). Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction. Heart rhythm : the official journal of the Heart Rhythm Society, 9(8), 1288-94. https://doi.org/10.1016/j.hrthm.2012.04.017

Vancouver

Barthel P, Bauer A, Müller A, Huster KM, Kanters JK, Paruchuri V o.a. Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction. Heart rhythm : the official journal of the Heart Rhythm Society. 2012 aug.;9(8):1288-94. https://doi.org/10.1016/j.hrthm.2012.04.017

Author

Barthel, Petra ; Bauer, Axel ; Müller, Alexander ; Huster, Katharina M ; Kanters, Jørgen K. ; Paruchuri, Vijayapraveena ; Yang, Xiaoyun ; Ulm, Kurt ; Malik, Marek ; Schmidt, Georg. / Spontaneous baroreflex sensitivity : prospective validation trial of a novel technique in survivors of acute myocardial infarction. I: Heart rhythm : the official journal of the Heart Rhythm Society. 2012 ; Bind 9, Nr. 8. s. 1288-94.

Bibtex

@article{a05f9e691d984397a75dbce91a33422c,
title = "Spontaneous baroreflex sensitivity: prospective validation trial of a novel technique in survivors of acute myocardial infarction",
abstract = "Low baroreflex sensitivity (BRS) indicates poor prognosis after acute myocardial infarction. Noninvasive BRS assessment is complicated by nonstationarities and noise in electrocardiogram and pressure signals. Phase-rectified signal averaging is a novel signal processing technology overcoming these problems.",
keywords = "Aged, Baroreflex, Blood Pressure, Diabetic Angiopathies, Electrocardiography, Female, Humans, Male, Middle Aged, Multivariate Analysis, Myocardial Infarction, Patient Selection, Prospective Studies, ROC Curve, Signal Processing, Computer-Assisted",
author = "Petra Barthel and Axel Bauer and Alexander M{\"u}ller and Huster, {Katharina M} and Kanters, {J{\o}rgen K.} and Vijayapraveena Paruchuri and Xiaoyun Yang and Kurt Ulm and Marek Malik and Georg Schmidt",
note = "Copyright {\textcopyright} 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.",
year = "2012",
month = aug,
doi = "10.1016/j.hrthm.2012.04.017",
language = "English",
volume = "9",
pages = "1288--94",
journal = "Heart Rhythm",
issn = "1547-5271",
publisher = "Elsevier",
number = "8",

}

RIS

TY - JOUR

T1 - Spontaneous baroreflex sensitivity

T2 - prospective validation trial of a novel technique in survivors of acute myocardial infarction

AU - Barthel, Petra

AU - Bauer, Axel

AU - Müller, Alexander

AU - Huster, Katharina M

AU - Kanters, Jørgen K.

AU - Paruchuri, Vijayapraveena

AU - Yang, Xiaoyun

AU - Ulm, Kurt

AU - Malik, Marek

AU - Schmidt, Georg

N1 - Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

PY - 2012/8

Y1 - 2012/8

N2 - Low baroreflex sensitivity (BRS) indicates poor prognosis after acute myocardial infarction. Noninvasive BRS assessment is complicated by nonstationarities and noise in electrocardiogram and pressure signals. Phase-rectified signal averaging is a novel signal processing technology overcoming these problems.

AB - Low baroreflex sensitivity (BRS) indicates poor prognosis after acute myocardial infarction. Noninvasive BRS assessment is complicated by nonstationarities and noise in electrocardiogram and pressure signals. Phase-rectified signal averaging is a novel signal processing technology overcoming these problems.

KW - Aged

KW - Baroreflex

KW - Blood Pressure

KW - Diabetic Angiopathies

KW - Electrocardiography

KW - Female

KW - Humans

KW - Male

KW - Middle Aged

KW - Multivariate Analysis

KW - Myocardial Infarction

KW - Patient Selection

KW - Prospective Studies

KW - ROC Curve

KW - Signal Processing, Computer-Assisted

U2 - 10.1016/j.hrthm.2012.04.017

DO - 10.1016/j.hrthm.2012.04.017

M3 - Journal article

C2 - 22516186

VL - 9

SP - 1288

EP - 1294

JO - Heart Rhythm

JF - Heart Rhythm

SN - 1547-5271

IS - 8

ER -

ID: 48052081