Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD. / Schou-Pedersen, Anne Marie Voigt; Lykkesfeldt, Jens.

I: Journal of Analytical Methods in Chemistry, Bind 2018, 6148515, 01.02.2018.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Schou-Pedersen, AMV & Lykkesfeldt, J 2018, 'Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD', Journal of Analytical Methods in Chemistry, bind 2018, 6148515. https://doi.org/10.1155/2018/6148515

APA

Schou-Pedersen, A. M. V., & Lykkesfeldt, J. (2018). Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD. Journal of Analytical Methods in Chemistry, 2018, [6148515]. https://doi.org/10.1155/2018/6148515

Vancouver

Schou-Pedersen AMV, Lykkesfeldt J. Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD. Journal of Analytical Methods in Chemistry. 2018 feb. 1;2018. 6148515. https://doi.org/10.1155/2018/6148515

Author

Schou-Pedersen, Anne Marie Voigt ; Lykkesfeldt, Jens. / Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD. I: Journal of Analytical Methods in Chemistry. 2018 ; Bind 2018.

Bibtex

@article{32e8e5bbf0e342e1a1f2508ae8b4573d,
title = "Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD",
abstract = "Increased asymmetric dimethylarginine (ADMA) in human plasma has been associated with reduced generation of nitric oxide, leading to atherosclerotic diseases. ADMA may therefore be an important biomarker for cardiovascular disease. In the present study, three sample preparation techniques were compared regarding the quantification of L-arginine and ADMA in human plasma: (A) protein precipitation (PP) based on aqueous trichloroacetic acid (TCA), (B) PP using a mixture of ammonia and acetonitrile, and (C) solid-phase extraction (SPE). The samples were analysed by using high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The analytical performance of (A) was comparable with that of (C), demonstrating recoveries of >90%, coefficient of variations (CVs, %) of <8, and a resolution (Rs) between ADMA and symmetric dimethylarginine (SDMA) of 1.2. (B) was disregarded due to recoveries below 75%. (A) was validated with good results regarding linearity (>0.994), precision (<5%), and sensitivity (lower limit of quantification (LLOQ)) of 0.14 µM and 12 nM for L-arginine and ADMA, respectively. Due to the simplicity and speed of procedure (A), this approach may serve as preferred sample preparation of human plasma samples before HPLC-FLD in providing important information regarding elevated ADMA concentrations.",
author = "Schou-Pedersen, {Anne Marie Voigt} and Jens Lykkesfeldt",
year = "2018",
month = feb,
day = "1",
doi = "10.1155/2018/6148515",
language = "English",
volume = "2018",
journal = "Journal of Analytical Methods in Chemistry",
issn = "2090-8865",
publisher = "Hindawi Publishing Corporation",

}

RIS

TY - JOUR

T1 - Comparison of Three Sample Preparation Procedures for the Quantification of L-Arginine, Asymmetric Dimethylarginine, and Symmetric Dimethylarginine in Human Plasma Using HPLC-FLD

AU - Schou-Pedersen, Anne Marie Voigt

AU - Lykkesfeldt, Jens

PY - 2018/2/1

Y1 - 2018/2/1

N2 - Increased asymmetric dimethylarginine (ADMA) in human plasma has been associated with reduced generation of nitric oxide, leading to atherosclerotic diseases. ADMA may therefore be an important biomarker for cardiovascular disease. In the present study, three sample preparation techniques were compared regarding the quantification of L-arginine and ADMA in human plasma: (A) protein precipitation (PP) based on aqueous trichloroacetic acid (TCA), (B) PP using a mixture of ammonia and acetonitrile, and (C) solid-phase extraction (SPE). The samples were analysed by using high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The analytical performance of (A) was comparable with that of (C), demonstrating recoveries of >90%, coefficient of variations (CVs, %) of <8, and a resolution (Rs) between ADMA and symmetric dimethylarginine (SDMA) of 1.2. (B) was disregarded due to recoveries below 75%. (A) was validated with good results regarding linearity (>0.994), precision (<5%), and sensitivity (lower limit of quantification (LLOQ)) of 0.14 µM and 12 nM for L-arginine and ADMA, respectively. Due to the simplicity and speed of procedure (A), this approach may serve as preferred sample preparation of human plasma samples before HPLC-FLD in providing important information regarding elevated ADMA concentrations.

AB - Increased asymmetric dimethylarginine (ADMA) in human plasma has been associated with reduced generation of nitric oxide, leading to atherosclerotic diseases. ADMA may therefore be an important biomarker for cardiovascular disease. In the present study, three sample preparation techniques were compared regarding the quantification of L-arginine and ADMA in human plasma: (A) protein precipitation (PP) based on aqueous trichloroacetic acid (TCA), (B) PP using a mixture of ammonia and acetonitrile, and (C) solid-phase extraction (SPE). The samples were analysed by using high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The analytical performance of (A) was comparable with that of (C), demonstrating recoveries of >90%, coefficient of variations (CVs, %) of <8, and a resolution (Rs) between ADMA and symmetric dimethylarginine (SDMA) of 1.2. (B) was disregarded due to recoveries below 75%. (A) was validated with good results regarding linearity (>0.994), precision (<5%), and sensitivity (lower limit of quantification (LLOQ)) of 0.14 µM and 12 nM for L-arginine and ADMA, respectively. Due to the simplicity and speed of procedure (A), this approach may serve as preferred sample preparation of human plasma samples before HPLC-FLD in providing important information regarding elevated ADMA concentrations.

U2 - 10.1155/2018/6148515

DO - 10.1155/2018/6148515

M3 - Journal article

C2 - 29484214

VL - 2018

JO - Journal of Analytical Methods in Chemistry

JF - Journal of Analytical Methods in Chemistry

SN - 2090-8865

M1 - 6148515

ER -

ID: 189148202