A free and simple computerized screening test for visual field defects

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

A free and simple computerized screening test for visual field defects. / Nordfang, Maria; Uhre, Valdemar; Robotham, Ro Julia; Kerry, Sheila J.; Frederiksen, Jette Lautrup; Starrfelt, Randi.

I: Scandinavian Journal of Psychology, Bind 60, Nr. 4, 05.07.2019, s. 289-294.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Nordfang, M, Uhre, V, Robotham, RJ, Kerry, SJ, Frederiksen, JL & Starrfelt, R 2019, 'A free and simple computerized screening test for visual field defects', Scandinavian Journal of Psychology, bind 60, nr. 4, s. 289-294. https://doi.org/10.1111/sjop.12546

APA

Nordfang, M., Uhre, V., Robotham, R. J., Kerry, S. J., Frederiksen, J. L., & Starrfelt, R. (2019). A free and simple computerized screening test for visual field defects. Scandinavian Journal of Psychology, 60(4), 289-294. https://doi.org/10.1111/sjop.12546

Vancouver

Nordfang M, Uhre V, Robotham RJ, Kerry SJ, Frederiksen JL, Starrfelt R. A free and simple computerized screening test for visual field defects. Scandinavian Journal of Psychology. 2019 jul. 5;60(4):289-294. https://doi.org/10.1111/sjop.12546

Author

Nordfang, Maria ; Uhre, Valdemar ; Robotham, Ro Julia ; Kerry, Sheila J. ; Frederiksen, Jette Lautrup ; Starrfelt, Randi. / A free and simple computerized screening test for visual field defects. I: Scandinavian Journal of Psychology. 2019 ; Bind 60, Nr. 4. s. 289-294.

Bibtex

@article{2d11894ae7144e60a5023c78e45fbded,
title = "A free and simple computerized screening test for visual field defects",
abstract = "About 30-40% of stroke patients suffer from visual field defects following injury. These can interfere with the standard neuropsychological assessment and complicate the interpretation of tests that use visual materials. However, information about the integrity of a patient's central visual field is often unavailable. We, therefore, designed a screening tool, the computerized visual field test (c-VFT), specifically targeted at providing easily available, but rough, information about patients' central visual field. c-VFT was tested in two samples of stroke patients. Eleven patients were tested on c-VFT and on the Esterman test. Five patients were tested on c-VFT and the Humphrey Visual Field Analyzer (HFA), central 10-2. Criterion validity of the c-VFT was investigated by calculating quadrantwise intraclass correlation for both comparisons. For the HFA comparison, we also calculated point-to-point intraclass correlation, sensitivity, and specificity. Analyses revealed moderately good correspondence between c-VFT and the Esterman test, and between c-VFT and HFA 10-2, respectively. When looking specifically at test points within one degree of visual angle apart in the two tests, intraclass correlation increased. For these points, the sensitivity of c-VFT was 0.89 and specificity was 0.97. While the c-VFT is not designed to be diagnostic nor to replace the detailed visual field analysis, this study shows that it provides a reasonable screening of the central visual field. The test can easily be used and will be made freely available to neuropsychological clinicians and researchers.The open access test can be found here: https://tinyurl.com/ysz9b28c",
keywords = "anopia, hemianopia, neuropsychological assessment, stroke, visual field screening",
author = "Maria Nordfang and Valdemar Uhre and Robotham, {Ro Julia} and Kerry, {Sheila J.} and Frederiksen, {Jette Lautrup} and Randi Starrfelt",
year = "2019",
month = jul,
day = "5",
doi = "10.1111/sjop.12546",
language = "English",
volume = "60",
pages = "289--294",
journal = "Scandinavian Journal of Psychology",
issn = "0036-5564",
publisher = "The Scandinavian Psychological Associations",
number = "4",

}

RIS

TY - JOUR

T1 - A free and simple computerized screening test for visual field defects

AU - Nordfang, Maria

AU - Uhre, Valdemar

AU - Robotham, Ro Julia

AU - Kerry, Sheila J.

AU - Frederiksen, Jette Lautrup

AU - Starrfelt, Randi

PY - 2019/7/5

Y1 - 2019/7/5

N2 - About 30-40% of stroke patients suffer from visual field defects following injury. These can interfere with the standard neuropsychological assessment and complicate the interpretation of tests that use visual materials. However, information about the integrity of a patient's central visual field is often unavailable. We, therefore, designed a screening tool, the computerized visual field test (c-VFT), specifically targeted at providing easily available, but rough, information about patients' central visual field. c-VFT was tested in two samples of stroke patients. Eleven patients were tested on c-VFT and on the Esterman test. Five patients were tested on c-VFT and the Humphrey Visual Field Analyzer (HFA), central 10-2. Criterion validity of the c-VFT was investigated by calculating quadrantwise intraclass correlation for both comparisons. For the HFA comparison, we also calculated point-to-point intraclass correlation, sensitivity, and specificity. Analyses revealed moderately good correspondence between c-VFT and the Esterman test, and between c-VFT and HFA 10-2, respectively. When looking specifically at test points within one degree of visual angle apart in the two tests, intraclass correlation increased. For these points, the sensitivity of c-VFT was 0.89 and specificity was 0.97. While the c-VFT is not designed to be diagnostic nor to replace the detailed visual field analysis, this study shows that it provides a reasonable screening of the central visual field. The test can easily be used and will be made freely available to neuropsychological clinicians and researchers.The open access test can be found here: https://tinyurl.com/ysz9b28c

AB - About 30-40% of stroke patients suffer from visual field defects following injury. These can interfere with the standard neuropsychological assessment and complicate the interpretation of tests that use visual materials. However, information about the integrity of a patient's central visual field is often unavailable. We, therefore, designed a screening tool, the computerized visual field test (c-VFT), specifically targeted at providing easily available, but rough, information about patients' central visual field. c-VFT was tested in two samples of stroke patients. Eleven patients were tested on c-VFT and on the Esterman test. Five patients were tested on c-VFT and the Humphrey Visual Field Analyzer (HFA), central 10-2. Criterion validity of the c-VFT was investigated by calculating quadrantwise intraclass correlation for both comparisons. For the HFA comparison, we also calculated point-to-point intraclass correlation, sensitivity, and specificity. Analyses revealed moderately good correspondence between c-VFT and the Esterman test, and between c-VFT and HFA 10-2, respectively. When looking specifically at test points within one degree of visual angle apart in the two tests, intraclass correlation increased. For these points, the sensitivity of c-VFT was 0.89 and specificity was 0.97. While the c-VFT is not designed to be diagnostic nor to replace the detailed visual field analysis, this study shows that it provides a reasonable screening of the central visual field. The test can easily be used and will be made freely available to neuropsychological clinicians and researchers.The open access test can be found here: https://tinyurl.com/ysz9b28c

KW - anopia

KW - hemianopia

KW - neuropsychological assessment

KW - stroke

KW - visual field screening

U2 - 10.1111/sjop.12546

DO - 10.1111/sjop.12546

M3 - Journal article

C2 - 31131452

VL - 60

SP - 289

EP - 294

JO - Scandinavian Journal of Psychology

JF - Scandinavian Journal of Psychology

SN - 0036-5564

IS - 4

ER -

ID: 218616946